Supply pressure p0 > p1 and value below p1 before reaching tout
If the upper pressure value p1 is not reached after the start of the measurement,
measurement of dT starts. "MEAS" then appears in the upper status bar. In the
lower status bar, the display alternates between the values for dP (pressure differ-
ence between p0 and the current pressure), dT (time period in seconds since
passing through p1), and QL. After tout has expired, "DONE" appears in the up-
per status bar, and the values for dP, dT, and QL appear alternately in the lower
status bar.
Press the center button to acknowledge the message and return the sensor to
u
measurement readiness.
Supply pressure p0 > p1 and values below p1 and p2 before reaching tout
If the upper pressure value P1 is not reached after the start of the measurement,
measurement of dT starts. "MEAS" then appears in the upper status bar. In the
lower status bar, the display alternates between the values for dP (pressure differ-
ence between p1 and p2), dT (time period in seconds since passing through p1
until reaching p2), and QL. If the value falls below the lower (pressure) threshold
P2, the display color changes from green to red.
There is a leak. Fig. 23 shows a schematic depiction of the leakage measurement.
"DONE" appears in the upper status bar, and the values for dP, dT, and QL appear
alternately in the lower status bar.
Press the center button to acknowledge the message and return the sensor to
u
measurement readiness.
9 Service and Maintenance
The device is maintenance-free.
Only use water and, if necessary, a mild cleaning agent for cleaning.
u
10 Disassembly and Exchange
System is under high pressure!
Danger of injury and system damage from uncontrolled system operating
states.
Make sure that the system component in which the pressure sensor is in-
u
stalled is not under pressure or voltage before beginning disassembly.
1. Make sure that the system is not under voltage or pressure.
2. Loosen and remove all connections.
3. Loosen the pressure sensor from the (threaded) pressure connection using a
wrench, or pull the pressure sensor straight out of the push-in fitting.
4. Dispose of the packaging and used parts in accordance with the regulations of
the country where used.
11 Error and Warning Messages
The display areas A and B blink in case of error and warning messages (Fig. 2).
Display
Cause
OL OVERPRESS
Applied pressure > end of
measuring range
UL UNDERPRES
Applied pressure < start of the
measuring range
ERR1 GEN.ERROR
General error
ERR2 SHORTOUT1
Short-circuit present at out-
put 1
ERR2 SHORTOUT2
Short-circuit present at out-
put 2
ERR3 OVERVOLTG
Supply voltage > 30 V DC
ERR4 LOW VOLTG
Supply voltage < 17 V DC
ATT1 SHIFT RP1
The switching point is set be-
low the existing resetting
ATT1 SHIFT RP2
point. The resetting point is
automatically set with the
smallest possible hysteresis
below the new switching
point.
AVENTICS™ PE5 | R412010843-BAL-001-AG | English
CAUTION
Remedy
Set the pressure within the
measuring range (see Figs. 21
and 22)
Contact us!
Rectify short-circuit and dis-
connect the supply voltage
temporarily so that the out-
put returns to normal opera-
tion.
1)
Correct the setting of the
supply voltage
1)
Press the center button to ac-
knowledge the message
Display
Cause
ATT2 ADJ>LIMIT
During zero point adjust-
ment, the applied pressure is
outside the permissible limit
of 5% of the range.
LOCK KEYLOCKED
If the key lock is active, the
system will attempt to go
into the programming mode.
WARN (p<p1)
The value for p0 is not at least
0.02 bar higher than the up-
per threshold value p1.
1)
The outputs switch off if the supply voltage exceeds 30 V DC or falls below
17 V DC.
If a second switch output is present, you can configure it as a diagnostic output.
In the extended programming functions (EF), select the value "DIA" for the
u
parameter "OUT2" g 8.8. Selecting the extended programming functions.
The diagnostic output and the digital outputs behave as follows in case of an er-
ror:
Display
Digital outputs
(area A)
PNP mode NPN mode
OL
Normal function
UL
ERR1
Low
High
Only pull-
Only pull-up
ERR2
down
ERR3
ERR4
12 Technical Data
General data
Dimensions (W x H x D)
Weight
Display
System pressure display
Update of the display
Protection class acc. to IEC 60529
Measuring ranges
Operating temperature range
Storage temperature range
Relative humidity
Shock load
Vibration load
Materials
Port
1)
Supply voltage
2)
Current consumption
Electrical safety
Switch outputs
Function
Switching voltage
Remedy
Press the center button to ac-
knowledge the message
Enter password
Press the center button to ac-
knowledge the message
Diagnostic output
Push-pull
PNP mode NPN mode
mode
Low
High
Only pull-
Only pull-up
down
Low
Low
High
Only pull-
Only pull-
Only pull-up
down
down
35 mm x 63 mm x 35 mm
Approx. 45 g
LCD, 4-digit, backlit
Selectable: bar, MPa, kPa, psi, and inHg
Settable: 1000, 500, 200, and 100 ms
IP65/67 with assembled connection ports
–1 ... 0 bar
0 ... +10 bar
–1 ... +1 bar
–1 ... +10 bar
0 ... +6 bar
0 ... +12 bar
0 ... 60°C
-20 ... 80°C
< 90%
Max. 30 g, xyz, DIN EN 60068-2-27
(11 ms, mechanical shock)
Max. 5 g, xyz acc. to IEC 60068-2-6
(10 to 150 Hz, vibration at resonance)
Housing: polycarbonate
Buttons: TPE
Mounting clip: POM
Seals: NBR
M12x1, 4-pin:
(outputs 2x digital and outputs 1x analog and
1x digital)
5-pin:
(outputs 2x digital, 1x analog, leakage mode:
outputs 1x digital, 1x analog, input 1x digital)
17 ... 30 V DC, protected against polarity re-
versal
Max. 40 mA (24 V)
Protection class III
PNP/NPN/push-pull, selectable (for the ver-
sion with IO link: switch output 1: IO link/PNP
and switch output 2: PNP/NPN/push-pull, se-
lectable)
Opener/closer, window/hysteresis function
freely adjustable
Supply voltage - 2 V
Push-pull
mode
Low
NPN active
Low NPN
Pull-down
22