About the water softener system
NORMAL OPERATION, CONTROL DISPLAYS
During normal operation, the present time of
day and AM or PM and DAYS TO EMPTY
show in the control display area.
FEATURE: OPTIONAL RECHARGE CONTROLS
Sometimes, a manually started recharge may
be desired or needed. Two examples:
You have used more water than usual
(house guests, extra washing, etc.) and you
may run out of soft water before the next
recharge.
The system ran out of salt.
Use one of the following features to start a
recharge immediately, or at the next preset
recharge start time.
FEATURE: MEMORY
If electrical power to the water softening system
is interrupted, the control display is blank, and
the blue indicator light is off, but the control
keeps correct time for 24 hours. When power
is restored, you have to reset the present time
only if the display and blue indicator light are
flashing. All other settings are maintained and
never require resetting unless a change is
desired.
FEATURE/SERVICE: AUTOMATIC ELECTRONIC DIAGNOSIS
The control computer has a self-diagnostic
function for the electrical system (except
input power and water meter). The computer
monitors the electronic components and circuits
for correct operation. If a malfunction occurs,
an error code appears in the control display.
The system will automatically recharge at the
preset recharge time as needed.
RECHARGE TONIGHT
Touch (do not hold) the RECHARGE button.
RECHARGE TONIGHT flashes in the control
display area. A recharge will occur at the next
preset recharge start time. If you decide to
cancel this recharge, touch the same button
once more.
RECHARGE NOW
Press and hold the RECHARGE button until
RECHARGE NOW starts to flash in the control
display area. The water softening system
begins an immediate recharge and, when over
in about two hours, you will have a new supply
of soft water. Once started, you cannot cancel
this recharge.
If the time is flashing after a long power outage,
the water softening system continues to work
as it should to provide you with soft water.
However, recharge may occur at the wrong
time of day until you reset the control to the
correct time of day.
5