Mounting and Fixing
Arraying
Small alterations to loudspeaker positions can have the eff ect of minimising problematic combing frequencies. Arrays should be constructed so that the individual
coverage patters of each loudspeaker combine with minimal overlap. The design of the VXP cabinet greatly simplifi es the creation of eff ective arrays, allowing
seamless wide horizontal coverage using two loudspeakers without the need for tedious experimentation.
By placing the VXP cabinets with the 30 degree angled rear panels together, minimal dispersion pattern overlap is achieved, guaranteeing an extraordinarily smooth
transition. In many applications the 90 or 75 degree dispersion pattern may be suffi cient in the horizontal plane. It is also possible to stack the cabinets vertically using
the above method (in a central cluster for example) where greater vertical dispersion is required. As shown in the above diagram, one of the VXP cabinets is inverted to
allow the optimum splay angle to be achieved. The grille can be simply removed from this cabinet and be replaced for matching orientation. The grille is held in
position by the two fi xing screws on the top and bottom lips of the cabinet.
The TANNOY Professional hardware covered in this guide has been designed to off er quick, simple, cost eff ective and secure solutions for mounting specifi c TANNOY
Professional loudspeakers. This hardware has been designed and manufactured with a high safety load factor for its specifi c role. To ensure the safest possible use of
the hardware covered in this guide, it must be assembled in strict accordance with the instructions specifi ed. The information in this Quick Start Guide relating to the
assembly and the safe use of these accessories must be understood and followed.
IMPORTANT NOTE: The mounting of a permanently installed sound system may be dangerous unless undertaken by qualifi ed personnel with the required experience
and certifi cation to perform the necessary tasks. Walls, fl oors or ceilings must be capable of safely and securely supporting the actual load. The mounting accessory
used must be safely and securely fi xed both to the loudspeaker and to the wall, fl oor or ceiling.
When mounting rigging components on walls, fl oors or ceilings, ensure that all fi xings and fasteners used are of an appropriate size and load rating. Wall and ceiling
claddings, and the construction and composition of walls and ceilings, all need to be taken into account when determining whether a particular fi xing arrangement
can be safely employed for a particular load. Cavity plugs or other specialist fi xings, if required, must be of an appropriate type, and must be fi tted and used in
accordance with the maker's instructions.
The operation of your speaker cabinet as part of a fl own system, if installed incorrectly and improperly, can potentially expose persons to serious health risks and
even death. In addition, please ensure that electrical, mechanical and acoustic considerations are discussed with qualifi ed and certifi ed (by local state or national
authorities) personnel prior to any installation or fl ying.
Make sure that speaker cabinets are set up and fl own by qualifi ed and certifi ed personnel only, using dedicated equipment and original parts and components
delivered with the unit. If any parts or components are missing please contact your Dealer before attempting to set up the system.
Be sure to observe the local, state and other safety regulations applicable in your country. MUSIC Group, including the MUSIC Group companies listed on the enclosed
"Service Information Sheet", assumes no liability for any damage or personal injury resulting from improper use, installation or operation of the product. Regular
checks must be conducted by qualifi ed personnel to ensure that the system remains in a secure and stable condition. Make sure that, where the speaker is fl own,
the area underneath the speaker is free of human traffi c. Do not fl y the speaker in areas that can be entered or used by members of the public.
Speakers create a magnetic fi eld, even if not in operation. Therefore, please keep all materials that can be aff ected by such fi elds (discs, computers, monitors, etc.)
at a safe distance. A safe distance is usually between 1 and 2 metres.
All manuals and user guides at all-guides.com
Technical Specifi cations
VX 5.2 (-WH)
System
Frequency response
87 Hz - 35 kHz ±3 dB
65 Hz - 45 kHz -10 dB
Nominal dispersion
120° H x 90° V @ -6dB points
90° conical @ -6dB point
Directivity factor (Q)
7.3
Directivity index (DI)
8.6
Power handling (IEC)
Passive
130 W continuous, 520 W peak
100 W continuous, 400 W peak
Bi-amp
Sensitivity
90 dB (1 W @ 1 m)
Maximum SPL
Passive
111 dB continuous, 117 dB peak
111 dB continuous, 117 dB peak
Bi-amp
Impedance
Passive
8 Ω
Bi-amp
Crossover Type
Passive with dynamic HF protection
Passive with dynamic HF protection
Components
1 x 5" (125 mm) LF driver
1 x 6" (150 mm) constant directivity
1 x 5" (125 mm) constant directivity
Dual Concentric
Enclosure
Connectors
2x Neutrik speakON* NL4
2x Neutrik speakON* NL4
1 x barrier strip terminals
1 x barrier strip terminals
Wiring
Pins 1+ / 1- Input, Pins 2+ / 2- Link
Pins 1+ / 1- Input, Pins 2+ / 2- Link
Passive
Bi-Amp
Dimensions H x W x D
334 x 181  x 201mm
(13.1  x 7.1 x 7.9")
Net weight
4.4 kg (9.7lbs)
Construction
12 mm (½ ") plywood, vented and
12 mm (½ ") plywood, vented and
internally braced
Finish
Semi matt black paint (white optional) Semi matt black paint (white optional) Semi matt black paint (white optional)
Grille
Powder coated perforated steel
Powder coated perforated steel
Flying hardware
M6 x 2 yoke bracket insert
M6 x 2 yoke bracket insert
(4 mm allen key)
M6 x 4 inserts
Compatible with industry
Compatible with industry
standard brackets
Blanking plate for optional VTH
Accessories
Multi Angle Wall Mount
Multi Angle Wall Mount
Multi Angle Wall Mount-WH
Multi Angle Wall Mount-WH
Yoke Horizontal VX 5.2/VX 6
Yoke Horizontal VX 5.2/VX 6
Yoke Horizontal VX 5.2/VX 6 - WH
Yoke Horizontal VX 5.2/VX 6 - WH
Quick Start Guide
VX 6 (-WH)
VX 8 (-WH)
VX 8M
92 Hz - 35 kHz ±3 dB
85 Hz - 35 kHz ±3 dB
85 Hz - 35 kHz ±3 dB
80 Hz - 45 kHz -10 dB
62 Hz - 45 kHz -10 dB
62 Hz - 45 kHz -10 dB
90° conical @ -6dB point
90° conical @ -6dB point
5.6
6.8
7
7.9
130 W continuous, 520 W peak
130 W continuous, 520 W peak
91 dB (1 W @ 1 m)
92 dB (1 W @ 1 m)
92 dB (1 W @ 1 m)
113 dB continuous, 119 dB peak
113 dB continuous, 119 dB peak
8 Ω
8 Ω
Passive with dynamic HF protection
Passive with dynamic HF protection
1 x 8" (200 mm) constant directivity
1 x 8" (200 mm) constant directivity
Dual Concentric
Dual Concentric
Dual Concentric
2x Neutrik speakON* NL4
2 x Neutrik speakON* NL4
1 x barrier strip terminals
Pins 1+ / 1- Input, Pins 2+ / 2- Link
Pins 1+ / 1- Input, Pins 2+ / 2- Link
334 x 226  x 216 mm
389 x 281 x 276 mm
389 x 281  x 316.7 mm
(13.1  x 8.9 x 8.5")
(15.3  x 11.1 x 10.9")
(15.3  x 11.1 x 12.5")
5.0 kg (11.0 lbs)
8.1 kg (17.8 lbs)
8.6 kg (18.9 lbs)
15 mm (5⁄8") plywood, vented and
15 mm (5⁄8") plywood, vented and
internally braced
internally braced
internally braced
Semi matt black paint
Powder coated perforated steel
Powder coated perforated steel
M10 x 2 yoke bracket insert
M10 x 3 fl ying inserts
(4 mm allen key)
(6 mm allen key)
(portrait mounting)
M6 x 4 inserts
M10 x 2 fl ying inserts
1 x Integrip carrying handle
Compatible with industry
Integral pole mount for standard
standard brackets
standard brackets
35 mm poles
M6 x 4 inserts
pole mount
Blanking plate for optional VTH
pole mount
1 x Integrip carrying handle
Multi Angle Wall Mount
Multi Angle Wall Mount-WH
Yoke Horizontal VX8
Yoke Horizontal VX8 - WH
VTH Top Hat
Yoke Vertical VX8/VX8.2
Yoke Vertical VX8/VX8.2 - WH
VTH Top Hat
11
6.8
9.2
8 Ω