Assembly
Attention! The fitting must be installed, flushed and
tested after the valid norms!!
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the sink.
3. Slip the plastic washer, the slide washer, the metall
washer and collar over the hoses and threaded
base and tighten the collar nut by hand. If there
is not enough space, please use only the slide
washer and the metal washer without the plastic
washer.
4. Tighten screws.
5. Connect the supply pipes to the isolation valves;
cold right - hot left.
The hot and cold water supply's should be of equal
pressures.
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.

Technical Data

Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow:
Hansgrohe single lever mixers can be used toge-
ther with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
To adjust the hot water limiter on single lever mixers,
please see page 13.
No adjustment is necessary when using a continuous
flow water heater.

English
Spare parts (see page 3)
1
1.1 screw cover
2
3
4
5
6
7
8
9
10
max. 1 MPa
1,6 MPa
max. 80° C
65° C
13 l/min 0,3 MPa
handle
flange
nut
cartridge cpl.
aerator cpl.
fixing set
connection hose 900 mm
sealing set
lever collar
support
97442000
94186000
96391000
94194000
92730000
13913000
95049000
98758000
96529000
97548000
97523000
Tabla de contenido