Updating Firmware - DJI T30 Guia Del Usuario

Ocultar thumbs Ver también para T30:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
Solid green
Blinks yellow three
times continuously
Blinks yellow four
times continuously
Blinks red once
continuously
Blinks red twice
continuously
Solid red
The warning indicator will light up if one of the following problems occur while using the battery station:
Warning Indicator
Solid yellow
Blinks yellow once
continuously
Blinks red once
continuously
Blinks red once
continuously
Solid red
If there are any abnormalities, connect the battery station to a remote controller and run the DJI
MG or DJI Agras app to check more information. If the app indicates that a module is abnormal or
broken, contact DJI or a DJI authorized dealer.

Updating Firmware

Follow the instructions below to update the firmware using the remote controller or DJI Assistant 2
for MG. Users will be notified through the app when firmware updates are available.
Using Remote Controller
1. Connect the battery station to a remote controller using a USB-C cable and connect the battery
station to a power outlet.
2. Power on the remote controller and press the power button on the operation panel to power on
the battery station.
3. Run the DJI MG or DJI Agras app and follow the prompts to update the firmware. Make sure the
remote controller remains connected to the internet while updating.
©
10
2021  DJI All Rights Reserved.
/
The temperature of the battery in the corresponding
/
The temperature of the battery in the corresponding
/
Beeps once
continuously
connected. This warning will only appear 10 seconds
Beeps twice
The connector short-circuited. Check the battery or
continuously
Beeps three times
continuously
Warning Sound
/
/
/
Beeps once
continuously
Beeps twice
continuously
The battery in the corresponding position to the
number is fully charged
position to the number is too low and the battery
station has stopped charging
position to the number is too high and the battery
station has stopped charging
The battery in the corresponding position is not
correctly connected or an unauthorized battery is
after the battery is connected
the battery station
Critical error detected
Description
Main board is abnormal and the power is limited
The CPX503-3000 switching power supply is
abnormal and the power is limited
The CPX503-3000 switching power supply is
unavailable or the fan stalled
The CPX503-3000 has experienced a critical error
and there is no output
Main board is abnormal and unavailable
Tabla de contenido
loading

Este manual también es adecuado para:

T10

Tabla de contenido