STEP 2 - ELECTRICAL CONNECTIONS
There are three ways to connect Uplift Tech depending on your cabinet's electrical option.
1. Allow 24" (610mm) of electric wire. Feed electric wire into opening on top of cabinet as shown.
2. Robern recommends the Maestro® C•L® Dimmer from LUTRON®, Model # MACL-153M.
http://www.lutron.com/TechnicalDocumentLibrary/369613a.pdf
Other LED control dimmers may operate with this product but have not been tested or verified. It's recommended that the dimmer be
within reach of your mirror so you can adjust the brightness.
For on/off (no dimmer) operation a standard wall switch may be substituted in place of the dimmer.
Connection for E2 and E4 - No Door Light
Connection for E2 and E4 - With Door Light and Programmable Night Light
© 2019 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
800.877.2376
www.robern.com
Installation instructions
All manuals and user guides at all-guides.com
Circuit Breaker
120 VAC
20A GFI
Wall-mounted
Circuit Breaker
Dimmer/switch
Black (L)
120 VAC
White (N)
20A GFI
Green (G)
Field Connection
Black (L)
White (N)
Green (G)
Field Connection
Black (L)
10
Cabinet Power Circuit
Black (L)
Black (L)
White (N)
White (N)
Ground (G)
Red (L)
Door
Light
Black (L)
Circuit
White (N)
White (N)
Black (L)
Black (L)
Cabinet
Power
White (N)
Circuit
White (N)
Ground (G)
Part no. 209-1311-rA rev. 06/13/19