Mounting; Electrical Installation - SICK WTB4FP MultiSwitch Instrucciones De Operación

Ocultar thumbs Ver también para WTB4FP MultiSwitch:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
4

MOUNTING

4
Mounting
en
5

Electrical installation

6
O P E R A T I N G I N S T R U C T I O N S | WTB4FP MultiSwitch
LED indicator green: supply voltage active
4
Mount the sensor using a suitable mounting bracket (see the SICK range of accesso‐
ries).
Figure 1: Alignment of the sensor relative to the object direction
Note the sensor's maximum permissible tightening torque of < 0,4 Nm.
Note the preferred direction of the object relative to the sensor, cf.
Operation in standard I/O mode:
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
Male connector connection: Pin assignment
Cable: Wire color
Only apply voltage/switch on the voltage supply once all electrical connections have
been established.
Operation in IO-Link mode: Connect the device to a suitable IO-Link master and inte‐
grate in the master or control via IODD/function block. The green LED flashes on the
sensor. IODD and function block are available to download from
the part number.
Explanations on connection diagram.
BN = brown
WH = white
BU = blue
BK = black
MF (pin 2 configuration) = external input, teach-in, switching signal
Q
/C = switching output, IO-Link communication
L1
Test = Test input
U
: 10 ... 30 V DC
B
see figure 1, page
6.
www.sick.com
under
8025665.1C7L/2021-09-03 | SICK
Subject to change without notice
Tabla de contenido
loading

Tabla de contenido