SICK WTT190LC Manual De Operación página 13

Ocultar thumbs Ver también para WTT190LC:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 72
5
TROUBLESHOOTING
12
LED indicator/fault pattern /
LED indicator/fault pattern
Green LED lights up, no output
signal when object is
detected /
Green LED lights up, no output
signal when object is detected
Green LED flashes /
Green LED flashes
Switching outputs not accord‐
ing to graphic F /
Switching outputs not accord‐
ing to graphic F
Switching outputs not accord‐
ing to graphic F /
Switching outputs not accord‐
ing to graphic F
Yellow LEDs flash at the same
time /
Yellow LEDs flash at the same
time
Yellow LED flashes (only
briefly) /
Yellow LED flashes (only briefly)
Yellow LED lights up, no object
in the path of the beam /
Yellow LED lights up, no object
in the path of the beam
Object is in the path of the
beam, yellow LED does not
light up /
Object is in the path of the
beam, yellow LED does not
light up
Cause /
Cause
Test input (Test) is not con‐
nected properly /
Test input (Test) is not con‐
nected properly
IO-Link communication /
IO-Link communication
IO-Link communication /
IO-Link communication
Parameter settings made
manually, which deviate from
the standard /
Parameter settings made
manually, which deviate from
the standard
The sensor is not ready for
operation. The sensor will be
in the warming-up phase at
low ambient temperatures.
The sensor will have shut
down at excessively high
ambient temperatures. /
The sensor is not ready for
operation. The sensor will be
in the warming-up phase at
low ambient temperatures.
The sensor will have shut
down at excessively high
ambient temperatures.
Teach-in mode /
Teach-in mode
Distance between the sensor
and the background is too
short /
Distance between the sensor
and the background is too
short
Distance between the sensor
and the object is too long or
sensing range is set too
short /
Distance between the sensor
and the object is too long or
sensing range is set too short
Measures /
Measures
If the power supply is OK,
replace the sensor
See the note on connecting
the TI /
See the note on connecting
the TI
-
-
Initiate a factory reset. The
switching outputs are reset to
factory settings. /
Initiate a factory reset. The
switching outputs are reset to
factory settings.
At low ambient temperatures,
wait until the sensor has
warmed up. Ensure the sensor
cools down at excessively high
ambient temperatures. /
At low ambient temperatures,
wait until the sensor has
warmed up. Ensure the sensor
cools down at excessively high
ambient temperatures.
Check the teach-in mode /
Check the teach-in mode
Reduce the sensing range,
see graphic F /
Reduce the sensing range,
see graphic F
Increase the sensing range,
see graphic F /
Increase the sensing range,
see graphic F
8024108 | SICK
Subject to change without notice