Mennekes AMTRON Xtra Serie Manual De Instrucciones página 56

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 199
Error code
Meaning
00
No error
10
Installation error
13
Overtemperature
15
Device time invalid
Energy Manager
16
connection error
30
Device start failed
31
Internal test failed
Charging cable
50
inserted incorrectly
Wrong charging
51
cable
Communication with
52
the vehicle inter-
rupted
102 (only with
operating
Maintenance
mode "SCU")
255
Unknown error
26
Trigger (examples)
Residual current device or
miniature circuit breaker
has triggered
Internal temperature sen-
sor has triggered (at >
60°C)
Invalid or no system time
No connection to the
Energy Manager
Device does not start or
is in the faulty state after
startup
Device does not start
Charging not possible
Charging not possible
Charging not possible
Maintenance of the ACU
is performed
Remedy
f Restart residual current devices and miniature circuit
breakers
Î "5.5.2 Restarting residual current devices and minia-
ture circuit breakers"
f Allow the device to cool down.
f Acknowledge fault.
f Connect with MENNEKES Charge APP.
f Check network and Energy Manager settings in the
service interface.
f Check the LAN / WLAN connection.
f Disconnect the device from the mains for three min-
utes and restart it.
f Acknowledge fault.
f Disconnect the device from the mains for three min-
utes and restart it.
f Acknowledge fault.
f Disconnect charging cable and plug in again.
f Check charging cable and replace if necessary.
f Disconnect the device from the mains for three min-
utes and restart it.
f If the LED info field is permanently lit:
Acknowledge the fault.
f Check charging cable and replace if necessary.
Once the maintenance has been completed, the fault has
been eliminated.
Tabla de contenido
loading

Tabla de contenido