EN
•
During operation, never get between the object and the equipment.
•
Monitor the situation of the equipment and the structure continuously while using the equipment.
•
Parts of an object that could fly off must be secured.
•
Never couple or uncouple couplers while the system is under pressure.
•
Use only genuine Holmatro accessories and ensure that they have been attached correctly.
•
Make sure that parts of the body never come between moving parts. There is a risk that parts of the
body may be crushed or cut.
•
Stop immediately if the system makes strange noises or displays aberrant behaviour.
•
Stop immediately if the equipment leaks oil. Oil escaping under pressure can penetrate the skin and
cause serious injury. Go immediately to a hospital with a person who is injected with oil for medical
help. Give a specification of the oil to the medical staff.
•
Always adhere to the safety regulations that apply to other equipment that is used in the operation.
2.6
Safety regulations with respect to maintenance
•
Wear personal means of protection when performing maintenance tasks.
•
Never work in a way that could jeopardize safety.
•
Make sure that the equipment cannot roll away or tip over. The control and drive must be switched
off and safeguarded against unexpected activation.
•
Make sure that moving parts do not move unexpectedly.
•
Used or leaked fluids, and any other products consumed during the activities, must be collected and
disposed of in a environmentally responsible way.
3
Description
3.1
Equipment
Depending on the model of hand or foot pump, it can be used for single- or double-acting hydraulic tools
operating on mineral oil and suitable for an allowable operation pressure of 720 bar. The maximum
available oil volume differs per pump. The pump can not be used for equipment which requires more oil
volume as stated in the technical specification of the particular pump.
3.2
Type designation
Example: PAX 18 H 2
/i
Pos.
Code
Description
1
P
pump (hand / foot pump range)
2
A
A = aluminium tank (standard range)
3
X
with X : 1000 Bar pump
without X: 720 Bar pump
4
18
total oil contents tank = 1800 cc (code x 100)
5
H
H = hand pump
F = foot pump
6
2
number of stages
28
All manuals and user guides at all-guides.com
916.001.313_000
PA