Cleaning The Air Filter - Sony VPL-X2000U Manual De Instrucciones

Ocultar thumbs Ver también para VPL-X2000U:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4
Replace the lamp cover and push to tighten the two
screws to fix the cover.
To reset the use time of the lamps in the
message display window
1
Plug in the power cord and set the projector to
standby mode.
2
Press the LIGHT, B, b and ENTER keys on the
control panel in sequence. Press each key within 5
seconds.
TIMER RESET?
LAMP: 1
3
Press the V or v key to display ALL.
TIMER RESET?
LAMP: ALL
4
Press the ENTER key.
TIMER RESET??
LAMP: ALL
5
Press the ENTER key again to reset the time.
The reset mode will be automatically cancelled.

Cleaning the Air Filter

The air filter should be cleaned in every 100 hours.
When it becomes difficult to remove the dust from the
filter, replace the filter with a new one.
1
Turn off the power of the projector and unplug the
power cord.
2
Remove the air filter cover on the bottom of the
projector.
3
Remove the air filter.
4
Remove the dust from the filter with a vacuum
cleaner.
5
Attach the air filter and replace the cover.
Notes
• If the air filter is excessively dirty, wash it with mild
detergent solution and dry it in a shaded place.
• Be sure to attach the air filter cover firmly; the power
will not be turned on if it is not closed securely.
49
(GB)
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Vpl-x2000eVpl-x2000m

Tabla de contenido