1 1 7 7 . . F F u u n n c c t t i i o o n n a a n n d d a a d d j j u u s s t t m m e e n n t t s s o o f f t t h h e e r r e e e e d d l l i i m m i i t t s s w w i i t t c c h h e e s s / /
p p e e r r m m a a n n e e n n t t m m a a g g n n e e t t s s
As standard, all drive portals are equipped with reed limit switches which
switch off the gate in its end positions "OPEN" and "CLOSED". The reed limit
switches for both directions are mounted in the internal console. The
permanent magnets included in the accessory pack are attached to the front of
the rack.
The distance between reed limit switch and permanent magnet must not exceed
10 mm! If the range of the permanent magnets is not sufficient, a stronger
permanent magnet can be used or an additional permanent magnet or spacer
(provided by customer) must be doubled.
Zahnstange
Reed-Endschalter
To adjust the permanent magnets, move the gate to the desired "OPEN" or
"CLOSED" position (as already described under 16.2). Attach the permanent
magnets to the gear rack opposite the corresponding reed limit switches. By
moving the permanent magnets you can readjust the end positions of the gate
even more precisely. Once the correct position of the permanent magnets has
been found, fix them with a screw in the hole provided on the gear rack.
The drives are delivered as standard in DIN left (or according to your request).