SPECIFICATIONS
Display: 3 3/4-digit LCD , max. reading 3999
Negative Polarity Indication: (
Over range Indication: (OL) shown on the display
Jaw Opening Capability: 33 mm
Max. Measurable Conductor: Ø 28 mm
Battery: 1.5V, AAA or equivalent, two pieces
Low Battery Indication:
Operation Environment: 0° - 40°C, <75%RH
Storage Environment: -10°C – 50°C, <85%RH
Size: 194 x 71 x 38 mm
Weight: about 215g (incl. batteries)
Accuracy is specified for a period of one year after calibration and at 23°C
up to 76%. Except where specified specially, accuracy is specified from 8 % to 100% of range.
Accuracy specifications take the form of:
±
([% of Reading]+[number of Least Significant Digits])
PANEL
1
Trigger is used to open and close the jaws.
2
Function / Range Switch is used to select desired function or range
as well as to turn on or off the meter.
3
Display
4
Socket (COM) to connect the black (negative) test lead.
5
Socket (+) to connect the red (positive) test lead.
6
Button (HOLD) is used to enter/exit the data hold mode.switch
between auto range mode and manual range mode as well as to
select desired manual range.
7
Button (SELECT)
a. When the rotary switch is in the ( ) position, pressing this
(SELECT) button to switch the meter between DC current and
AC current measurement function.
b. When the rotary switch is in the (
(SELECT) button to switch the meter between diode and
continuity test function.
8
Button (∆/DCA"0") in current measurements, this button can be
used for zeroing before measurement. In other measurements, this
button can be used to enter or exit relative mode. The (DCA"0")
button must be pressed for compensation of measurement error in
the 400A range.
9
Tactile Barrier
10 Jaw used for clamping the conductor for current measurements.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Digital Multimeter with Clamp
for DC and AC Current
-
) shown on display
shown on the display
Tel.: 02196 720480
Fax.: 02196 7204820
) position, pressing this
BGS 2202
±
5°C, with relative humidity
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed
Tabla de contenido
loading

Tabla de contenido