CAUTION
Important information about measurement categories
Use this meter only for measurements of measurement categories I, II and III, never use this meter for
measurement category IV measurements.
Measurements on circuits that have no direct connection to the network (battery
CAT I
operation), e.g. Devices of protection class 3 (operation with safety extra-low
voltage), battery-operated devices, conventional car electrical system.
Measurements on circuits that have a direct connection via plug to the low-voltage
CAT II
network, e.g. Household appliances, portable electrical appliances.
Measurements within the building installation, including stationary consumers with
CAT III
non-pluggable connection, distributor connection, permanently installed devices in
the distributor, e.g. Sub-distribution.
Measurements at the source of the low voltage installation, including counters, main
CAT IV
connection, primary overcurrent protection, e.g. counter, low voltage overhead line,
house connection box.
ELECTRICAL SYMBOLS
Alternating Current
Direct Current
Caution, risk of danger, refer to the operating manual before use.
Caution, risk of electric shock.
Earth (ground) Terminal
Conforms to European Union directives
The equipment is protected throughout by double insulation or reinforced Insulation.
TECHNICAL DATA
This meter is a 3-3/4 digit auto range digital clamp meter for measuring DC and AC voltage, DC and
AC current, resistance, diode and continuity. It is easy to operate and is an ideal measurement tool.
AC Voltage
Range
4.000V
40.00V
400.0V
600V
Input Impedance: 10 MΩ
Frequency Range: 40Hz - 400Hz
Max. Permitted Input Voltage: 600V rms
Response: Average, calibrated in rms of sine wave
DC Voltage
Range
400.0 mV
4.000V
40.00V
400.0V
600V
Input Impedance: range 400mV: > 100 MΩ, the other ranges: 10MΩ
Max. Permitted Input Voltage: 600V dc
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Resolution
1mV
10mV
100mV
1V
Resolution
0.1mV
1mV
10mV
100mV
1V
Tel.: 02196 720480
Fax.: 02196 7204820
Accuracy
± (1.2%+5)
± (1.5%+5)
Accuracy
± (0,8%+5)
± (1.0%+5)
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed