Channel-to-Channel Failover

In addition to entire amplifier failover, AudiaFUSION supports channel-to-channel failover, which is triggered by one of the following conditions:
• Heat Sink alarm
• Short Circuit alarm*
• Channel Failure alarm
The wire failover link cable is not required when wiring channel-to-channel failover.
Parallel Wiring
2
1
The redundant channel can be wired in parallel to the existing speaker line (shown above) or connected to a redundant speaker line.
The primary amplifier module will resume control after the fault condition is cleared and the unit is re-powered.
* A Short Circuit alarm will cause failover only if the Persistent Short Circuit Delay time property in the AudiaFUSION is exceeded.
AudiaFUSION REAR PANEL
Redundant Wiring