12
Pump Operating Modes
The IntelliFlo
1. Manual Operation: Speed buttons 1-4 can be programmed for Manual operation. This
means the speed button is pressed and then the start button and the pump runs a programmed
speed. Speeds 5-8 cannot be programmed for Manual operation because there are no buttons
associated with them.
To operate the pump in Manual Mode, press one of the four speed buttons, and press the
Start/Stop button to run the assigned speed for that button. When the pump is running a
Manual Speed Setting (speed 1, 2, 3 or 4 button pressed manually) and a scheduled speed is
set to run, the scheduled speed will take priority regardless of speed (RPM) assigned to each
button. When the Scheduled Speed's time is over, it will not revert back to the manually
pressed speed. If the pump is running a schedule and a speed button is pressed manually, the
pump will run the manually selected speed until the next scheduled speed program.
2. Egg Timer (Duration): Speeds 1-4 can be programmed to run for a duration of time once
pressed. This means that the Speed button is pressed and then the start button and the pump
runs a programmed speed and the speed will turn off at the end of a preprogrammed amount
of time. Speeds 5-8 have no direct pump speed buttons and therefore cannot be programmed
with an Egg-Timer.
3. Schedule: The speed button can be programmed to turn on and off at a certain time. The
LED above the Start/Stop button must be lit for the pump to run schedules. When a speed is
set to run in Schedule mode it can still be operated manually. When a speed is programmed
to run 23 hours and 59 minutes per day it will not turn off. For example, for the pump to run
24 hours per day, program the pump to start at 8:00 AM and stop at 7:59 AM.
Programming the Pump
When the pump is running at a manual speed and password time out is activated the pump can be turned
off but it cannot be turned back on. Pressing the Start/Stop button places it in the Running Schedule
mode. Therefore, it will only run Speeds that are Scheduled to come on at their scheduled Start Time.
VSD pump can be programmed three ways:
®