Operation
5.2.3 Total Days of Operation
To obtain this reading, press the timer reset button two times in succession and follow steps as outline in
Section
5.1.3, regarding the operation of this feature.
5.2.4 Lamp Failure (Blank Screen)
Refer to
Note: On the VIQUA systems, the audible tone provided for lamp failure is a continuous alarm, rather than the intermittent
(1 second on, 1 second off) condition on the basic VIQUA systems.
5.2.5 Solenoid Output
Working in conjunction with the UV intensity monitor, the VIQUA controller provides a powered (line voltage) IEC solenoid
output connector. (Note: this is not a dry contact) This solenoid output is protected with a replaceable 2 amp isolated fuse.
Connection from this output to the solenoid can be done using the IEC solenoid power cable PN 260135. When the UV
intensity monitor senses that the water is not adequately being treated and drops to 49% UV intensity or below, the internal
relay is opened thereby stopping AC power flowing to the normally closed solenoid valve. The valve will remain closed (no
power) until the UV level rises above 49%, at which time the solenoid will open, allowing for water to pass through. (To
temporarily enable the operation of this solenoid output for up to 12 hours, please refer to the instructions outlined in
Section
5.2.1).
Note: During bypass, do not consume the water until the system has returned to a safe condition.
5.2.6 4-20mA Output (Optional)
To achieve the capability to transmit the UV intensity data to a remote location via a 4-20 mA signal, use an optional "Y"
cable (PN 260134) is available from your dealer. The "Y" cable comes with 20 meters (65') of cable for the 4-20 mA signal.
15
Section 5.1.5
for explanation of this feature.
Figure 1 Solenoid Installation
Optional
Solenoid
Valve