ADVANCE-GRP[GD]
• ГОСТ IEC 60079-1-2011,
• ГОСТ Р МЭК 60079-7-2012,
• ГОСТ IEC 60079-31-2010
• Electrical Equipment
(EN 60947-1:2007 + A1:2011, EN 60947-3:2009 + A1:2012)
(IEC 60947-1:2007 + A1:2010, IEC 60947-3:2008 + A1:2012)
They are manufactured and tested in accordance with directive ATEX directive 2014/34/EU, IECEx scheme, EAC Ex certification
state-of-the-art engineering practice and ISO 9001.
2. TECHNICAL DATA
2.1 TYPE OF PROTECTIONS
• ATEX / IECEx:
Ex db eb IIC T
Gb - Ex tb IIIC T80°C Db IP66
(1)
Tamb.
- Tcable:
(2)
(3)
• EAC Ex:
1Ex d e IIC T
Gb X - Ex tb IIIC T80°C Db X IP66
(1)
Tamb.
- Tcable:
(2)
(3)
(1)
Temperature Class for Gas according to the table 1.
Ambient temperature range according to the table 1 when different from –20°C to +40°C.
(2)
(3)
Tcable: 80°C for type 504.16... when maximum ambient temperature is +60°C.
Tcable: 85°C for type 504.32... when maximum ambient temperature is +60°C.
Tcable: 90°C for type 504.63... when maximum ambient temperature is +60°C.
Tcable: 85°C for type 504.125...
2.2 CERTIFICATES
Atex Certificate: INERIS 15 ATEX 0017 X
IECEx Certificate: IECEx INE 15.0033 X
EAC Ex Certificate НАНИО ЦСВЭ № TC RU C-IT.AA87.B.00870
2.3 AMBIENT TEMPERATURE RANGE
ADVANCE-
Ambient
GRP[GD]
Temperature Range
Socket Type (*)
-50°C to +50°C
504.16...
-50°C to +60°C
-50°C to +60°C
-50°C to +50°C
-50°C to +40°C
504.32...
-40°C to +60°C
-40°C to +50°C
-40°C to +40°C
-35°C to +60°C
504.63...
-35°C to +50°C
-35°C to +40°C
504.125...
-35°C to +40°C
Table 1 - Ambient temperature range.
(*) For EAC Ex version add the "-xx.RU" suffix, to all code showed in the table.
MP39683
Temperature
CLASS - Gas
(Ta)
T6
T5
T4
T4
T5
T4
T4
T5
T3
T3
T4
T4
Optional Auxiliary Contacts
CORTEM M-053x TECHNOR ZBWE
--
--
--
--
--
--
Yes
Yes
--
--
Yes
--
15
Max. Surface
Temperature -
Dust
Yes
Yes
--
--
Yes
--
T80°C
--
Yes
--
--
Yes
--
ZP90904-5