Troubleshooting; Technical Data - ProMinent DHV-RM Instrucciones De Servicio

Válvulas delimitadoras de excesos de caudal
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Fault
Pressure drops below
set level
Setting pressure cannot
Leak at diaphragm (5)
Leak at adjusting screw (13)
Materials
Item*
2
Spring dome
4
Thrust washer
8
Compression spring
7
Spring plate
5
Formed diaphragm
3
Separating disc
10
Piston
15
Valve seat seal
22
Connection seal
1
Valve body
12
Connecting screw
1
2
PTFE with carbon;
PTFE pure white,
* For item numbers see Fig. 4 and 5
®
Viton
is a registered trademark of DuPont Dow Elastomers.
ProMinent
®
Troubleshooting / Technical Data
7

Troubleshooting

(see Fig. 4)
Cause
Valve seat seal (15)
or
valve seat defective
Diaphragm (5) defective
Valve installed wrong way
Contact pressure diaphragm
tension too low
Diaphragm (5) defective
8

Technical Data

Storage and transport temperature:
The backpressure valve must not be exposed to frost!
Combination options:
The backpressure valve can be used together with the metering
pumps G5, Vario, Sigma, Hydro, Meta, Makro TZ and Makro/ 5.
PP1
PC1
PP-GFK
PP-GFK
PP
PP
Galvanized Galvanized Galvanized
steel
steel
PP
PP
EPDM/PTFE laminated
PP
PVC
PP
PVC
EPDM
FPM
®
EPDM
Viton
A
PP
PVC
V2A
V2A
3
envelope ring PTFE/Viton
Corrective measures
Replace valve seat seal (15)
Consult ProMinent
Replace diaphragm (5)
(Chapter 6)
Turn valve
(observe direction arrow)
Retighten screws (12)
(approx. 6 Nm)
Replace diaphragm (5):
(Chapter 6)
PV1
TT1
PP-GFK
PP-GFK
PP
PP
Galvanized
steel
steel
PP
PP
2
PVDF
PTFE
2
2
PTFE
PTFE
FPM/PTFE
FPM/PTFE
®
3
Viton
A
PTFE
1
PVDF
PFTE
V2A
V2A
®
SS1
PP-GFK
PP
Galvanized
steel
PP
2
PTFE
2
PTFE
FPM/PTFE
3
PTFE
1.4571
V2A
23
Tabla de contenido
loading

Tabla de contenido