Safety Information; Assembly & Operation - Cadac TRIO POWER PAK Manual De Instrucciones

Ocultar thumbs Ver también para TRIO POWER PAK:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to
avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation
Read these instructions carefully so as to familiarise yourself with the appliance before fi ting the appliance to a gas cylinder.
1. General
• The CADAC Trio is a light weight, compact LPG source for CADAC and other camping products, it replaces a gas cylinder and regulator.
You fi t the gas cartridges into the Trio Power Pak and then to a camping stove or BBQ.
• This regulator complies with EN16129:2013 and SANS 1539:2017.
• Appliance category: I3B(28-30mbar) All EU, NO, IS, CH, TR, DE, AT and LU
• Appliance category: I3B(50mbar) DE, AT and LU
• Only to be used with EN417 type disposable cartridges (CADAC CAN220G).
• The Trio Power Pak is to be used only in the horizontal position.
• Gas appliances require ventilation for effi cient performance and to ensure the safety of users and other persons in close proximity.
• The Power Pak is fi tted with a regulator with a maximum supply rate of 1.0kg/hour.
• The user may adjust the supply rate of the Power Pak unit by turning the control valve on the Power Pak from fully closed to fully open.
AT=Austria
BE=Belgium
CH=Switzerland
DE=Germany
SI=Slovenia

2. Safety information

The Trio Power Pak is guaranteed for a period of 2 years against factory faults.
Natural wear and tear and valve components are excluded. Warranty excludes
damage caused by improper handling, misuse or repair by an unauthorized LP gas
dealer. Liability is limited to replacement of products. Never use in an unventilated
room with all windows and doors closed.
Never place the Trio Power Pak on a stove, and always keep it at least 1 meter away
from any source of heat (Fig. 1), and ensure it is not placed in an environment
where the temperature will exceed 40°C.
Always store, transport or use the Trio Power Pak in a horizontal position as seen in
images in this guide.
When not in use, keep the valve closed.
Do not use an appliance which is leaking, damaged or which does not operate
properly (malfunctioning).
If you suspect a gas leak, soapy water must be applied to the joints (the appliance
must not be fully immersed in soapy water as this may result in an unsafe operation
of the appliance). Any leakage will be seen as bubbles coming from the leakage
point. If you cannot remedy any leakage, unscrew the gas cartridge from the
appliance and return the appliance to your stockist.
The appliance should only be used in a well-ventilated location (minimum
ventilation requirement 5m3/h) in order to satisfy offi cial ventilation standards for
the supply of suffi cient combustion air and to avoid the dangerous building up of
unburned gases.
Gas cartridges must be fi tted or changed in a well-ventilated location, preferably
outside and away from any sources of ignition, such as naked fl ames, pilots,
electric fi res and away from other people.
Never leave the appliance unattended when in use.
Do not modify the appliance. Do not use it for anything for which it has not been designed.
3. Assembly & Operation
First ensure the control knob on the Trio Power Pak is in the "off" position.
Ensure that the hose is connected securely to the valve outlet of the Power Pak (Fig. 2).
Connect the other end of the hose securely to the appliance you wish to operate, using the hand wheel to tighten (Fig. 3).
1: Hand wheel (17mm Hex) and hose component
2: Move the handle wheel to the end of the hose sliding it over the brass nut.
3: Connect brass nut to the inlet of the BBQ, turn the hand wheel to tighten.
503-0766 LEV2 (370) Trio Power Pak K3 - User Manual (All).indd 1
CAUTION
must be provided.
IMPORTANT
Retain these instructions for future reference.
Country name abbreviations
DK=Denmark
GB=UnitedKingdom
ES=Spain
IE=Ireland
FI=Finland
IT=Italy
FR=France
NL=Netherlands
1 1
NO=Norway
PL=Poland
PT=Portugal
SE=Sweden
1m
1m
Valve outlet
Low pressured
gas
High pressured gas
Fig. 2
GB
1m
1m
Fig. 1
2019/12/19 15:19:45
Tabla de contenido
loading

Este manual también es adecuado para:

370

Tabla de contenido