All manuals and user guides at all-guides.com
OPERATING MODES
UK
AUTO
AUTOMATIC
Press the ON-OFF button on the remote control. Press the MODE button to
select the AUTO mode, the word AUTO will come up on the display screen.
In "AUTO" mode, the electronic control automatically selects the operating mode
according to the room temperature (measured by the sensor incorporated into
the Internal Unit):
- if the room temperature drops below 22°C, the heating cycle begins, and stays
on until the temperature rises above 24°C.
In the cooling only models, the ventilation cycle will start.
- if the room temperature rises above 26°C, the cooling cycle begins, and stays
on until the temperature drops below 24°C.
- if the room temperature is included between 22°C and 24°C, the dehumidifi-
cation cycle will begin.
The "AUTO" mode can also be enabled using the selector situated beneath the
front panel on the Internal Unit.
COOLING
Press the ON-OFF button on the remote control. Press the MODE button to
select the cooling mode, the symbol
will come up on the display screen. In
this mode, the air conditioning unit cools down the room while at the same time
reducing the humidity in the air. Set the desired room temperature using the
TEMP UP/DN buttons. The appliance regulates the compressor's operation cycles
automatically in order to keep the room at the desired temperature.
Example: if the temperature in the room is 28°C, you should set a temperature
below 27°C for the compressor to start and the cooling to begin.
DEHUMIDIFICATION
Press the ON-OFF button on the remote control. Press the MODE button to
select the dehumidification mode, the symbol
will come up on the display
screen.
This mode, with its alternating cooling and ventilation cycles, is designed to
obtain the dehumidification of the air without the room temperature being alte-
red considerably. Operation is completely automatic: the appliance regulates
the fan speed itself. If the temperature of the room exceeds the temperature set
using the remote control by two degrees, the appliance operates in cooling
mode with the fan operating at low speed.
If the ambient temperature is lower than the temperature set using the remote
control by 2°C, then the appliance comes to a stop.
If the room temperature is 2°C lower or higher than the temperature set, using
the remote control, the alternating operation will be enabled; the air conditioning
unit will run on cooling mode for six minutes and will stop for four minutes, an
interval during which the internal unit fan will operate at low speed.
ALTERNATING CYCLE DIAGRAM
TIME
cooling
ventilation
ventilation
cooling
only
only
21