– Position the measuring tool (without turning it) at a dis-
tance of 5 m so that the crossing point of the laser lines
is on the already marked point II and that the 0° laser
line runs through the point III.
Mark the 45° laser line at a distance of 5 m (Point IV).
– Turn the measuring tool by 45° so that the centre of the
0° laser line runs through the point IV.
The crossing point of the laser lines must still be on the
point II.
Mark the 45° laser line at a distance of 5 m as point V.
– Turn the measuring tool by 45° so that the centre of the
0° laser line runs through the point V.
The crossing point of the laser lines must still be on the
point II.
Mark the 45° laser line at a distance of 5 m as point VI.
1 609 92A 1Z2 | (1.7.16)
– Turn the measuring tool by 45° so that the centre of the
0° laser line runs through the point VI.
The crossing point of the laser lines must still be on the
point II.
– Mark the centre of the 45° laser line at a distance of
5 m as point VII as near as possible next to the point I.
– The difference of the two points VII and I is the actu-
al deviation of the 0° laser line and the 45° laser line.
The measuring length 4 x5 m= 20 m has a maximum ad-
missible deviation of: 20 mx±0.4 mm/m*= ±8 mm.
Therefore, the maximum difference between the points
I and VII may be 8 mm or less.
*The value ±0.4 mm/m results from the angle accuracy
±0.2 mm/m plus a possible uncertainty of 0.2 mm/m
while turning.
In case of uneven positioning
or fixing, the angle is smaller than 45° and 90° .
The width of the laser line changes with the distance.
The measuring tool is not self-levelling. There-
fore, the line on the wall is distorted.