Bosch Professional GTL 3 Manual Original página 17

Ocultar thumbs Ver también para Professional GTL 3:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
OBJ_BUCH-828-006.book Page 17 Friday, July 1, 2016 12:52 PM
For this check, you need a free surface of approx.
10 x5 m on a stable and even base.
Should the measuring tool exceed the maximum deviation
during one of the tests, please have it repaired by a Bosch
after-sales service.
– Position the measuring tool in one of the corners of the
measuring surface. Switch on the measuring tool and
align it so that the 0° laser line runs along the long side
of the measuring surface and that the 90° laser line
runs along the short side of the measuring surface.
10 m
– Mark the crossing point of the laser lines on the floor
(Point I). Mark also the centre of the 0° laser line at a
distance of 5 m (Point II) and at a distance of 10 m
(Point III).
– Position the measuring tool (without turning it) at a dis-
tance of 5 m so that the crossing point of the laser lines
is on the already marked point II and that the 0° laser
line runs through the point III.
Mark the centre of the 90° laser line at a distance of
5 m (Point IV).
Bosch Power Tools
English |
– Turn the measuring tool by 90° so that the centre of the
0° laser line runs through the point IV.
The crossing point of the laser lines must still be on the
point II.
– Mark the centre of the 90° laser line at a distance of
5 m as point V as near as possible next to the point I.
– The difference of the two points V and I is the actual
deviation of the 0° laser line and the 90° laser line from
the right angle.
The measuring length 2 x5 m= 10 m has a maximum ad-
2 mm.
missible deviation of: 10 mx±0.2 mm/m= ±
Therefore, the maximum difference between the points
I and V may be
2 mm or less.
– Position the measuring tool in one of the corners of the
measuring surface. Switch on the measuring tool and
align it so that the 0° laser line runs along the long side
of the measuring surface and that the 90° laser line
runs along the short side of the measuring surface.
10 m
– Mark the crossing point of the laser lines on the floor
(Point I). Mark also the centre of the 0° laser line at a
distance of 5 m (Point II) and at a distance of 10 m
(Point III).
1 609 92A 1Z2 | (1.7.16)
loading