GB
switched off with the keypad locked.
To use the hob, unlock the keypad by pressing button
T2.
NOTE: if none of the buttons on the keypad are
pressed for more than 1 minute during the
adjustment stage, the appliance exits the function
automatically.
SAFETY TIMES FOR EACH BURNER:
SAFETY TIMES FOR EACH BURNER:
SAFETY TIMES FOR EACH BURNER:
SAFETY TIMES FOR EACH BURNER:
SAFETY TIMES FOR EACH BURNER:
The safety time when the appliance is switched off
(the interval between the flame being switched off
and subsequent P.C.B. reaction, namely re-
ignition) is less than 10 seconds.
The safety time (the interval between the opening of
the valve and its closure if no flame is detected;
this coincides with the maximum spark duration) is
6 seconds.
BREAKDOWN SITUATIONS AND RESULTING
BREAKDOWN SITUATIONS AND RESULTING
BREAKDOWN SITUATIONS AND RESULTING
BREAKDOWN SITUATIONS AND RESULTING
BREAKDOWN SITUATIONS AND RESULTING
BEHAVIOUR OF THE APPLIANCE:
BEHAVIOUR OF THE APPLIANCE:
BEHAVIOUR OF THE APPLIANCE:
BEHAVIOUR OF THE APPLIANCE:
BEHAVIOUR OF THE APPLIANCE:
1 - Flame monitoring device breakage: the burner
cannot remain lit and therefore enters its safety
mode. A fault signal is shown on the display.
2 - No sparks: it is not possible to light the burner.
The P.C.B. blocks the gas supply to the burner
after the safety time has elapsed.
3 - Tap seizes up in any of the operating positions:
the burner loses its ability to modulate the flame
but can still be switched off and left in safe mode.
4 - The magnet seizes up in an open position: it is,
nevertheless, possible to switch the appliance off.
5 - The magnet seizes up in a closed position: it is
not possible to light the burner.
6 - Any breakdown of the P.C.B. will mean that it is
not possible to operate the appliance at all.
22

DATA PLATE

Electrical
voltage of 230V ~ 50Hz (see data
connections
plate )
This appliance conforms to the
following European Economic
Community directives:
-2006/95/EEC dated 12/12/2006
(Low Voltage) and subsequent
amendments
- 2004/108/EEC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2209/142/EEC dated 30/11/09
(Gas) and subsequent
amendments.
- 2002/96/EC and subsequent
amendments.