Electrical connection

GB
THE EQUIPMENT MUST BE EARTHED CORRECTLY.
The hobs are designed for operation with an alternating
current at the power supply voltage and frequency
indicated on the data plate (this is located underneath
the hob; alternatively the information may be found at
the end of the instruction manual). Make sure that the
local power supply voltage value is the same as the
value indicated on the data plate.
Connecting the power supply cable to the mains.
Connecting the power supply cable to the mains.
Connecting the power supply cable to the mains.
Connecting the power supply cable to the mains.
Connecting the power supply cable to the mains.
If direct connection to the electricity mains supply is
required, an omnipolar switch with a minimum contact
opening of 3 mm must be installed between the
appliance and the mains. The switch must be suitable
for the charge indicated and must comply with current
electrical regulations.
The yellow-green wire must not be interrupted by the
switch.
The supply cable must not be placed in areas where it
could reach temperatures higher than 50 °C.
If the appliance is to be installed above a built-in
electric oven, the electrical connection of the hob and
the oven must be performed separately, both for
electrical safety purposes and to make extracting the
oven easier.
Do not use reduction devices, adaptors or shunt
devices, as these may cause overheating or burning.
Before connecting the appliance to the power supply,
make sure that:
• The modulating valve and the electricity supply can
withstand the maximum power of the appliance (see
the data plate for details);
• The supply system is earthed correctly, in
compliance with current laws and regulations;
• The power socket or omnipolar switch may be
reached easily once the hob has been installed.
WE HEREBY DECLINE ALL LIABILITY WHEREVER
ACCIDENT PREVENTION LEGISLATION HAS NOT
BEEN OBSERVED.
Replacing the cable
Replacing the cable
Replacing the cable
Replacing the cable
Replacing the cable
! The cable must be checked regularly and
! The cable must be checked regularly and
! The cable must be checked regularly and
! The cable must be checked regularly and
! The cable must be checked regularly and
replaced by outhorised technicians only.
replaced by outhorised technicians only.
replaced by outhorised technicians only.
replaced by outhorised technicians only.
replaced by outhorised technicians only.
Use a H05RR-F rubber cable (or H05VV-F cable for
non-/CS models) with a cross-section of 3 x 0.75 mm².
The yellow-green wire should be 2 or 3 cm longer than
the other wires.
20

Gas connection

• Check that the appliance is set for the type of gas
available and then connect it to the mains gas
piping or the gas cylinder in compliance with
current regulations and standards.
• This appliance is designed and set to work with the
gas indicated on the label situated on the actual
hob. If the gas supply is other than the type for
which the appliance has been set, proceed with
replacing the corresponding nozzles (provided),
following instructions given in the paragraph
"Adaptation to different types of gas".
• For trouble-free operation, suitable use of energy
and longer life of the appliance, make sure that the
supply pressure complies with the values indicated
in the table 1 "burners and nozzles specifications,
otherwise install a special pressure regulator on the
supply pipe in compliance with current standards
and regulations.
• Connect in such a way that the appliance is
subjected to no strain whatsoever.
Either a rigid metal pipe with fittings in compliance
with the standards in force must be used for
connecting to the nipple union (threaded ½"G male
fitting) situated at the rear of the appliance to the
right (Fig.6), or flexible steel pipe in compliance with
the standards in force, which must not exceed 2000
mm in length.
fig.6
Should it be necessary to turn the fitting, the gasket
(supplied with the appliance) must be replaced. Upon
completion of installation, check the gas circuit, the
internal connections and the taps for leaks using a
soapy solution (never a flame). Also check that the
connecting pipe cannot come into contact with
moving parts which could damage or crush it. Make
sure that the natural gas pipe is adequate for a
sufficient supply to the appliance when all the
burners are lit