Devices with special features

8

Troubleshooting

8008782.Z474 | SICK
Subject to change without notice
0
+
1
2
Figure 8: Time functions
WSE24-2xx4x: with static front-screen heating for use in environments with gradual
temperature changes within the +5 °C ... +15 °C range.
WS/WE24-2V530S01: M12 male connector, 5-pin, glass front screen, dynamic power
heating on the rear side of the glass, current consumption: sender 150 mA, receiver
140 mA. The dynamic power heating is automatically switched on and off depending on
the ambient temperature (23-26 °C). For the use of quick temperature changes in the
range of <0 °C...+10 °C
The Troubleshooting table indicates which measures are to be taken if the sensor stops
working.
Table 10: Troubleshooting
LED indicator/fault pattern
Yellow LED does not light up
even though the light beam is
aligned to the receiver and
there is no object in the path of
the beam
No object in beam path, no out‐
put signal
Yellow LED flashes; if Alarm is
present then take note of the
corresponding output signal
0.5 ... 10 sec.
0.5 ... 10 sec.
Cause
No voltage or voltage below
the limit values
Voltage interruptions
Sensor is faulty
Test input (Test) is not con‐
nected properly
Sensor is still ready for opera‐
tion, but the operating condi‐
tions are not ideal
Measures
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Ensure there is a stable power
supply without interruptions
If the power supply is OK,
replace the sensor
Check connection of the test
input. When using female
cable connectors with LED
indicators, make sure the test
input is assigned correspond‐
ingly.
Check the operating condi‐
tions: Fully align the beam of
light (light spot) with the
13