GYROS (GAS POWERED)

GAS CONNECTION

All the gas connection, transformation and pressure control operations must be performed
by authorised personnel who must have specific technical skills and special abilities in the
specific sector. This also applies for all extraordinary maintenance operations such as lu-
brication and/or faucet replacement and thermocouple or burner replacement.
Equip the appliance gas supply tube with a faucet to be able to cut of gas supply in the event
of need.
The faucet (not supplied with the appliance) must be installed in a visible and accessible
position in order to easily identify its operating status (open or closed).

GAS SUPPLY TRANSFORMATION

The appliance is marketed with indications of the gas mains used by the manufacturer for
inspections.
If the gas mains do not correspond to the one used for inspection, before connecting the
gas mains, the installation technician must "transform" the appliance and indicate the type
EN
of gas in use on the plate.
Important
After "transforming" the appliance to the gas mains in use, make sure there are no
gas leaks or operating defects, test the appliance and indicate the type of gas in use
on the identification plate.
To "transform" and adapt the appliance to the gas mains in use, close the gas supply faucet
and perform the listed operations.
– burner nozzle replacement
– Heat power adjustment to minimum
- 19 -