To set the dip-switches/jumpers; turn off the power to the programmer, change the settings and then
switch the power back on.
Jumper J1
"SEL-CSP"
safety edge selection 8.2 kΩ
Pos A:
Pos B:
safety edge selection NC-contact
Jumper J2
"CSPF ENABLE"
Inserted:
digital safety edge enabled
Disinserted:
digital safety edge disabled
Jumper J3
"SEL_FTC"
Inserted:
the photocells will also block the motor when they are in alarm
Disinserted:
the photocells will only act as a safety device when the shutter is closing
Jumper J4
"EMRG ENABLE"
Inserted:
emergency manoeuvre enabled
Disinserted:
emergency manoeuvre disabled
Jumper J5
"REMOTE MEMO"
Inserted:
memorisation via radio enabled
Disinserted:
memorisation via radio disabled
Time programming procedure
-
Maximum work time: 180 seconds
-
Maximum pause time:
1) Press and hold down button "P1" PROG until LED "L2" lights up.
2) Close the rolling shutter completely using button "P2" MEMO/DEL (this action is carried out in the
"manual mode").
3) Press button "P1" to start the opening manoeuvre.
4) When the rolling shutter arrives at the completely open position and the opening travel limit activates,
cutting off power to the motor, wait 3-4 seconds and then press "P1" again; the LED "L2" will start
to flash indicating that the pause time count has started.
5) The next time you press "P1" the pause time will stop and the rolling shutter will begin to close.
6) When the shutter is completely closed and the closing travel limit activates, cutting off power to the
motor, wait 3-4 seconds and then press "P1"; at this point time programming has ended and LED
"L2" will switch off.
Note: after activating the programming procedure, step 2 can also be carried out by pressing the button
"TC", and from step 3 onwards you may proceed using the opening button "TA" (instead of "P1").
Attention! If at the end of time programming the LEDs "L2" and "L3" flash simultaneously the opera-
tion was not successful and you will have to repeat the procedure from step 1.
60 seconds
12
Tabla de contenido
loading

Este manual también es adecuado para:

Prg304Prg304e

Tabla de contenido