The word "Gal" remaining alongside the flow
rate refers to the register of the Totals (Reset or
NON Reset) which are again displayed when
exiting from the flow rate reading mode.
IMPORTANT: Even though in this mode they
are not displayed, both the Reset Total and the
General Total (Total) increase. Their value can
be checked after dispensing has terminated,
returning to "Normal" mode, by quickly
pressing CAL.
Use 2x1.5 V alkaline batteries size AAA.
WARNING
meter should be installed in a position
allowinG the batteries to be replaced
without removinG it from the system
Meter features two low-battery alarm levels:
1. When the battery charge falls below the
first level on the LCD, the fixed battery
symbol appears. In this condition, meter
continues to operate correctly, but the
Samoa Industrial, S.A. · Box 103 Alto Pumarín · 33211 Gijón - Asturias Spain · Tel.: +34 985 381 488 · Fax.: + 34 985 384 163
Operating mode
Daily use
Partial reset (flow rate mode)
To reset the Partial Register, finish dispensing
and wait for the Remote Display to show a
Flow Rate of 0.0 as indicated in the illustration
then quickly press RESET.

Maintenance

Replacement battery

fixed icon warns the user that it is
ADVISABLE to change the batteries.
2. If meter operation continues without
changing the batteries, the second
battery alarm level will be reached which
will prevent operation. In this condition
the battery icon starts to flash and is the
only one to remain visible on the LCD.