The appliance must be used with flexible
tubing intended to be fitted onto ringed
connectors on appliance and regulator sides,
fixed by collars (Standard XP D 36-110).
Appliance
Check that the flexible hose stretches out
normally without twisting or pulling and does
not come into contact with the hot sides of
the appliance. It should be replaced when
the expiry date on the hose is passed or
whenever it is damaged or develops surface
cracks.
Do not pull or pierce the hose. Keep away
from any parts of the appliance that get hot.
To use the equipment with the flexible
hose XP D 36-110:
Fitting the tubing: follow the assembly
instructions supplied with the flexible tubing
and collars.
Check for gas leaks following the instructions
in paragraph D.
belgium, Luxembourg, United Kingdom,
Ireland, Portugal, Spain, Italy, Croatia,
Greece, Netherlands, Czech republic,
Slovakia, Hungary,
Sweden, Denmark, Finland, bulgaria,
Turkey, romania, Poland:
The barbecue is equipped with a circular
connector. It should be used with flexible
hose that is suitable for use with butane
and propane gas. Hose length should not
exceed 1.20 metre. It should be replaced if
it is damaged or cracked, when required by
national regulations or at the end of the part
lifecycle. Do not pull or pierce the hose.
Keep away from any parts of the barbecue that
get hot. Check that the flexible hose stretches
out normally, without twisting or pulling.
Check for gas leaks following the instructions
in paragraph D.
M 20x1,5
Regulator
Slovenia, Norway,
- 10 -
D - CONNECTING
CYLINDER
If replacing an empty cylinder, read Section
F): «Removing or changing the gas
cylinder».
When installing or removing a gas cylinder,
always operate in an open, well-ventilated
place, never in the presence of a flame,
spark or any other source of heat (cigarette,
electrical appliance, etc.), and away from
other persons or inflammable materials.
- Position the gas cylinder on the ground,
behind or beside the appliance.
- Close the regulator or gas cylinder valve.
- Screw or click the regulator onto the cylinder
or onto the gas cylinder valve.
- Close the stove valves by turning the knobs
clockwise, position (
- Check that the tubing lies normally, without
twisting or stress.
- Check that the burner tube air holes at
the injector are not obstructed by dust or
spider's webs.
Gas leaks
Do not check for leaks using a flame. Use a
gas leak detecting liquid.
- Apply gas leak detecting liquid to the
cylinder/relief valve/pipe/stove unions.
- The control knobs should remain as set (
- Open the gas supply (valve or lever on the
relief valve).
- Any gas leaks will be indicated by bubbles.
- Tighten the collars if fitted to stop the leak.
Replace any defective parts. The stove
must not be used until all leaks have been
eliminated.
- Close the valve on the gas cylinder.
THE
GAS
).
).
Tabla de contenido