whether the power supply has the correct polarity or
grounded, have it checked by a qualified electrician.
Use 120V, 60Hz, and properly grounded branch circuit
protected by a 15-amp or 20-amp circuit breaker or time
delay fuse.
Electrial Connections
Shock Hazard: This appliance must be properly
grounded.Failure to do so can result in electric shock.
Electrical Requirements - 120-volt, 60 Hertz,properly
grounded circuit protected by a 15-amp or 20-amp circuit
breaker or time delay fuse. It is recommended that a
separate circuift serving only this range be provided.
Note: Use of automatic, wireless, or wired external
switches that shut off power to the appliance are not
recommended for this product.
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three prong grounding plug
for your protection against shock hazard and should be
plugged directly into a properly grounded three-pronged
receptacle.
Where a standard two-prong wall receptacle is encountered,
it is the responsibility and obligation of the customer to have
it replaced with a properly grounded three-prong wall
receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE
THE THIRD (GROUND)PRONG FROM THE POWER CORD. DO
NOT USE AN ADAPTER.
DO NOT USE AN EXTENSION CORD.
8.
Connect Range to Gas Supply
1)
Connect Range to Gas Supply
Most localities will require that the stove shutoff valve and
gas connections be installed by a certified technician or
plumber. These instructions are for a professional. Gas
installation specifications and regulations may vary so please
consult your local codes before proceeding.
1
Install a manual gas line shut-off valve in the gas line as
follows:
in an easily accessed location outside the range.
•
•
in the gas piping external to the appliance.
2
Install 1/2" male flare union adapter to 1/2"NPT
internal thread elbow at inlet of regulator.
On models equipped with standard twin burners, install the
male pipe thread end of the 1/2" flare union adapter to the
1/2" NPT internal thread at inlet of pressure regulator. Use a
wrench on the regulator fitting to avoid damage.
Install 1/2"
male flare union adapter to the NPT
3
internal thread of the manual shut-off valve, to secure the
shut-off valve to keep it from turning.
The gas supply pressure for checking the regulator
4
setting is 6 in.w.c. (Nature Gas) and 11 inch.w.c.(LP Gas)
connect flexible gas line connector to the regulator on the
range. Position range to permit connection at the shut-off
valve.
When all connections have been made, make sure all
5
range controls are in the position and turn on main gas
supply valve.
Leak testing of the appliance shall be conducted
6
according to the manufacturer's instructions. Use some soap
water (50% water and 50% soap) or a leak detector at all
9