7 Operation
6.5 Connecting the pneumatic system
A compressed air hose with a min. inner width of
means of a G1/4" screw connection (not included). A compressed air shut-off valve in the supply line is recommended. This
allows the TCS Compact to be quickly and simply depressurized if installation or maintenance work are required.
Cleaning stroke cylinder
up
down
Z1
(Pneumatic motor)
4
2
14
14
12
5
1
3
cylinder
Fig. 23
Connecting the pneumatic system
7 Operation
NOTICE
• Consult the documentation for the welding components.
• Ensure that the TCS Compact is only ever operated when using the protective device supplied.
• Only qualified personnel are permitted to perform work on the device or system.
1 Switch on the robot control system.
2 Start the welding process.
3 Stop the welding process.
EN - 30
ø
6 mm is required as a supply line. This is fastened to the housing by
Pneumatic motor
M
1
S1
Loosen the
clamping cylinder/
Close wire cutter
Z2
S2
Y2
Y1
12
45°
4
2
14
14
14
12
5
1
3
Close the
Vacuum output
clamping cylinder/
Open wire cutter
Compressed air
Y4
2
14
10
1
3
Y3
12
4
2
14
12
5
1
3
TCS Compact
Return
Anti-spatter
fluid
Suction
Min. 6 bar
BAL.0617.0 • 2021-05-20