10.6 Service kits
Warning
Before starting work on the pump, make
sure that the fuses have been removed or
the mains switch has been switched off.
Make sure that the power supply cannot
be accidentally switched on.
All rotating parts must have stopped
moving.
The following service kits are available for all pumps.
Service kit
Contents
Shaft seal kit
Shaft seal complete
O-ring kit
O-rings and gaskets for oil screws
Impeller complete with adjusting screw, shaft
Impeller
screw and key
1 litre of oil, type Shell Ondina X420. See
Oil
section
required quantity in oil chamber.
Lifting bracket Lifting bracket and screw
A possible replacement of the cable must
Note
be carried out by Grundfos or a service
workshop authorized by Grundfos.
10. Maintenance and service
Pump type
All
All
All
All
SL1.50.65.09
SL1.50.65.11
SL1.50.65.15
SLV.65.65.09
SLV.65.65.11
SLV.65.65.15
for
All types
0.9 - 1.5 kW
2.6 kW
10.7 Contaminated pumps
Warning
If a pump has been used for a liquid which
is injurious to health or toxic, the pump will
be classified as contaminated.
If you request Grundfos to service the pump, contact
Grundfos with details about the pumped liquid, etc.
before returning the pump for service. Otherwise
Grundfos can refuse to accept the pump for service.
Possible costs of returning the pump must be paid by
the customer.
However, any application for service (no matter to
whom it may be made) must include details about
the pumped liquid if the pump has been used for
liquids which are injurious to health or toxic.
The pump must be cleaned in the best possible way
before it is returned.
Product
Material
number
BQQP
96106536
BQQV
96645161
NBR
96115107
FKM
96646049
96115096
96115097
96115098
96115110
96115099
96115100
96586753
96984147
96984148
23