TAW AND TAS SERIES
TARGET PRESETS (PSET)
PSET function gives user ability to configure 10 preset target torque or target angle settings, each with
a target, minimum, maximum (over range) and batch count value. PSETs are stored in non-volatile
memory so that they are retained while power is off.
Note: After adding a Preset (see below), navigate between manual target torque, angle mode
and PSET screen by repeatedly pressing ENTER button. While PSET screen is displayed, press
UP/DOWN buttons to select additional configured PSETs.
STD
SLIM/SCR
ADDING A TORQUE PRESET
1. From manual target torque screen, select units of measure.
2. Press and hold UNITS button for 3 seconds.
3. ADD PRESET confirmation screen is displayed. Highlight YES menu selection using UP/DOWN
buttons then press ENTER button. NO menu selection returns to main menu without adding a PSET.