TROUBLEShOOTING

PROBLEM
• Light will not illuminate
• Battery pack will not charge. • Battery pack not inserted into charger. • Insert battery pack into
• Unit shuts off abruptly.
For assistance with your product, visit our website www.blackanddecker.com for the
location of the service center nearest you or call the BLACK & DECKER help line at
1-800-544-6986.
MAINTENANCE
Use only mild soap and damp cloth to clean the tool. Never let any liquid get inside the tool; never
immerse any part of the tool into a liquid.
IMPORTANT: To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment
(other than those listed in this manual) should be performed by authorized service centers or other
qualified service personnel, always using identical replacement parts.
ACCESSORIES
wARNING:
The use of any accessory not recommended for use with this tool could
be hazardous.
Recommended accessories for use with your tool are available from your local dealer or authorized
service center. If you need assistance regarding accessories, please call: 1-800-544-6986.
ThE RBRC™ SEAL
The RBRC™ (Rechargeable Battery Recycling Corporation) Seal on the lithium-ion
battery (or battery pack) indicates that the costs to recycle the battery (or battery
pack) at the end of its useful life have already been paid by Black & Decker. In
some areas, it is illegal to place spent lithium-ion batteries in the trash or municipal
solid waste stream and the RBRC program provides an environmentally conscious
alternative.
RBRC in cooperation with Black & Decker and other battery users, has established programs in the
United States and Canada to facilitate the collection of spent lithium-ion batteries. Help protect our
environment and conserve natural resources by returning the tool to an authorized Black & Decker
service center for recycling. You may also contact your local recycling center for information on
where to drop off the spent battery, or call 1-800-8-BATTERy.
POSSIBLE CAUSE
• Battery pack not installed properly.
• Battery pack not charged.
• Charger not plugged in.
• Surrounding air temperature
too hot or too cold.
• Battery pack has reached its
maximum thermal limit.
• Out of charge. ( To
maximize the life of the
battery pack it is designed
to shutoff abruptly when
the charge is depleted.)
11
POSSIBLE SOLUTION
• Check battery pack
installation.
• Check battery pack
charging requirements.
charger until LED illuminates.
• Plug charger into a
working outlet. Refer to
"Important Charging Notes"
for more details.
• Move charger and battery
pack to a surrounding air
temperature of above
40 degrees F (4,5°C) or
below 105 degrees F
(+40,5°C).
• Allow battery pack to cool
down.
• Place on charger and
allow to charge.