16 | English
5 Area measurement button
6 Length measurement button
7 Display
8 Alignment aid
9 Measuring button
10 Volume measurement button
11 Memory retrieve button "M="
12 Tracking (continuous measurement) button
13 Laser warning label
14 Latch of battery lid
15 Battery lid
16 Laser beam outlet
17 Reception lens
18 Serial number
19 Laser viewing glasses*
20 Laser target plate*
21 Protective pouch
* The accessories illustrated or described are not included as standard delivery.
Display Elements
a Measuring functions
Length measurement
Tracking (continuous measurement)
Area measurement
Volume measurement
b Battery low indicator
c Temperature warning
d Measured value/result
e Unit of measure
f Measurement reference level
g Laser switched on
h Individual measured value (for length measurement: result)
i Measured values stored

Technical Data

Digital Laser Rangefinder
Article number
Measuring range
Measuring accuracy (typically)
Lowest indication unit
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
Laser beam diameter (at 25 °C) and at 10 m dis-
tance, approx.
Batteries
Rechargeable batteries
Battery live, approximately
– Individual measurements
– Continuous measurement
2 609 140 620 | (14.7.11)
PLR 25
3 603 K16 200
A)
0.05–25 m
B)
±2.0 mm
1 mm
C)
– 10 °C ... +50 °C
– 20 °C ... +70 °C
90 %
2
635 nm, <1 mW
6 mm
4 x 1.5 V LR03 (AAA)
4 x 1.2 V KR03 (AAA)
D)
30000
D)
5 h
Bosch Power Tools
Tabla de contenido
loading

Este manual también es adecuado para:

3 603 k16 200

Tabla de contenido