Exhaust Direction - Eudora T24 Guia De Instalacion

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
Installation/Operation Supplement

Exhaust Direction

The dryer can be exhausted to the outdoors through the
back, left, right or bottom of the dryer. EXCEPTION:
Gas dryers cannot be vented out the left side
because of the burner housing.
Number of
90° Elbows
0
1
2
3
4
Maximum length of 102 mm (4 in.) diameter flexible metal duct
0
1
2
3
4
NOTE: Deduct 1.8 m (6 ft.) for each additional elbow.
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
14
Recommended
102 mm
(4 in.)
Maximum length of 102 mm (4 in.) diameter rigid metal duct
19.8 m (65 ft.)
16.8 m (55 ft.)
14.3 m (47 ft.)
11.0 m (36 ft.)
8.5 m (28 ft.)
13.7 m (45 ft.)
10.7 m (35 ft.)
9.1 m (30 ft.)
7.6 m (25 ft.)
6.1 m (20 ft.)
Weather Hood Type
Use Only for Short Run Installations
102 mm
(4 in.)
D673I
Table 2
64 mm
(2-1/2 in.)
D802I
16.8 m (55 ft.)
14.3 m (47 ft.)
12.5 m (41 ft.)
9.1 m (30 ft.)
6.7 m (22 ft.)
10.7 m (35 ft.)
8.2 m (27 ft.)
6.4 m (21 ft.)
5.2 m (17 ft.)
4.5 m (15 ft.)