Gas Requirements

NOTE: This manual is only a supplement. Refer to
installation/operation manual for full instructions.

Gas Dryers

(6.2 kW)
3
Gas Rate = 0.55 m
/hr
NOTE: This appliance must be installed in
accordance with regulations in force.
NOTE: This machine is supplied from the factory
for operation on Natural Gas [2nd Family, Group H
(E)] at nominal inlet pressure of 20 mbar for use in
the countries of GB/IE/PT/ES/IT. For installation in
other EU Countries, and/or for conversion to
L.P. (Liquefied Petroleum) gas, consult the
distributor. DO NOT connect the dryer to L.P. gas
without consulting the distributor and/or without
performing the proper conversion according to the
conversion instructions (Conversion Kit 599P3).
Natural Gas Altitude Adjustments
Altitude
m
ft.
#
915
3000
43
1830
6000
44
2440
8000
45
2740
9000
46
3050
10,000
47
Table 1
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
511472 (EN)
Orifice Size
Part No.
mm
in.
2.26
0.0890
503778
2.18
0.0860
58719
2.08
0.0820
503779
2.06
0.0810
503780
1.99
0.0785
503781
Installation/Operation Supplement
The unit must be isolated from the gas supply piping
system by closing the equipment shut-off valve during
any pressure testing of the gas supply piping system at
test pressures equal to or less than 50 mbar.
WARNING
To reduce the risk of gas leaks, fire or
explosion:
• The dryer must be connected to the type
of gas as shown on nameplate located
in the door recess.
• Use a new flexible stainless steel
connector.
• Use pipe joint compound insoluble in
L.P. (Liquefied Petroleum) Gas, or Teflon
tape, on all pipe threads.
• Purge air and sediment from gas supply
line before connecting it to the dryer.
Before tightening the connection, purge
remaining air from gas line to dryer until
odor of gas is detected. This step is
required to prevent gas valve
contamination.
• Do not use an open flame to check for
gas leaks. Use a non-corrosive leak
detection fluid.
• Any disassembly requiring the use of
tools must be performed by a suitably
qualified service person.