10
TECHNICAL DATA
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
Object with 90 % remission (based on standard
1)
white DIN 5033)
Limit value; operation in short-circuit protection
2)
mains max. 8 A; residual ripple max. 5 Vss
With light / dark ratio 1:1
3)
4)
valid for Q\ on Pin2, if configured with software
Signal transit time with resistive load
5)
6)
A = UV-connections reverse polarity protected
B = inputs and output reverse-polarity protected
C = Interference suppression
6
-3Pxx6x
-3Pxx1x
200 ... 300 µs
300 ... 450 µs
5) 4)
IP66,IP67,IP69K
IP66,IP67,IP69K
III
III
A,B,C
A,B,C
6)
-40 °C ... +60 °C
-40 °C ... +60 °C
-3Pxx1xS14
< 2.5 ms
5) 4)
IP66,IP67,IP69K
III
A,B,C
6)
6)
-40 °C ... +60 °C
Subject to change without notice
5) 4)
8020418 | SICK