34. TECHNICAL CHARACTERISTICS

Boiler model BOYLER DIGIT
Category
Rated heat input
Reduced heat input
Rated heat output
Reduced heat output
Efficiency according to Directive 92/42/EEC
Max. pressure in central heating system
Capacity of expansion vessel
Capacity of storage boiler
Pressure of expansion vessel
DHW production at outlet ∆T=30°C
Max. pressure in DHW system
DHW production at ∆T=25 °C
DHW production at ∆T=35 °C
Specific output (*)
Type
Diameter of concentric flue duct
Diameter of concentric air duct
Diameter of 2-pipe flue duct
Diameter of 2-pipe air duct
Diameter of flue duct
Max. mass flow of fumes
Min. mass flow of fumes
Fumes temperature max.
Fumes temperature min.
NOx class
Type of gas
G20 natural gas supply pressure
G31 propane supply pressure
Power supply voltage
Input frequency
Rated electrical input
Net weight
Dimensions
Protection against humidity and water penetration (**)
(*) according to EN 625
(**) according to EN 60529
As WESTEN constantly strives to improve its products, it reserves the right to modify the information contained in this document at any time and without
prior notice. This document is issued purely for the sake of information and should not be considered as a contract with third parties.
INSTRUCTIONS FOR FITTERS
240/40 i
II
2H3+
kW
27,1
kW
11,9
kW
24,4
kcal/h
21.000
kW
10,4
kcal/h
8.900
HH
bar
3
l
7,5
l
40
bar
0,5
l/30min
350
bar
8
l/min
14
l/min
10
l/min
14,5
B
11BS
mm
mm
mm
mm
mm
140
kg/s
0.022
kg/s
0,021
°C
110
°C
82
3
G20
G30-G31
mbar
20
mbar
37
V
230
Hz
50
W
110
kg
62
height
mm
950
width
mm
600
depth
mm
466
IP X5D
60
240/60 i
280/60 i
240/40 Fi
II
II
II
2H3P
2H3+
2H3+
27,1
31,1
26,3
11,9
11,9
11,9
24,4
28
24,4
21.000
24.080
21.000
10,4
10,4
10,4
8.900
8.900
8.900
HH
HH
HHH
3
3
3
7,5
7,5
7,5
60
60
40
0,5
0,5
0,5
390
450
350
8
8
8
14
16,1
14
10
11,5
10
18,2
19
14,5
B
B
C12 - C32 - C42 - C52 - C82 - B22
11BS
11BS
60
100
80
80
140
140
0,022
0,024
0,018
0,021
0,021
0,017
110
115
134
82
82
108
3
3
3
G20
G20
G20
G31
G30-G31
G30-G31
20
20
20
37
37
37
230
230
230
50
50
50
110
110
190
53
53
71
950
950
950
600
600
600
466
466
466
IP X5D
IP X5D
IP X5D
240/60 Fi
280/60 Fi
II
II
2H3P
2H3+
26,3
30,1
11,9
11,9
24,4
28
21.000
24.080
10,4
10,4
8.900
8.900
HHH
HHH
3
3
7,5
7,5
60
60
0,5
0,5
390
450
8
8
14
16,1
10
11,5
18,2
19
60
60
100
100
80
80
80
80
0,018
0,018
0,017
0,018
134
142
108
108
3
3
G20
G20
G30-G31
G31
20
20
37
37
230
230
50
50
190
190
63
63
950
950
600
600
466
466
IP X5D
IP X5D
926.008.2 - EN