To set the boiler parameters, press R and
shows "F01" alternating with the value of the relative parameter.
Change parameters
• To scroll the parameters press +/-
• To modify individual parameters press +/-
• To save the value press P. "MEM" appears on the display;
• To exit without saving, press
Factory settings
Type of boiler
F01
10 = sealed chamber - 20 = open chamber
Type of gas
F02
00 = NATURAL GAS - 01 = LPG
F03
Hydraulic system
Programmable relay 1 setting
F04
(02 = zone system - See Service instructions)
Programmable relay 2 setting
F05
(See Service instructions)
F06
Ext probe configuration (See Service instructions).
F07...F12
Manufacturer information
F13
CH max. heat output (0-100%)
F14
DHW max. heat output (0-100%)
F15
CH min. heat output
Maximum temperature setpoint (°C) setting
F16
00 = 85°C - 01 = 45°C
Pump overrun time in CH mode
F17
(01-240 minutes)
Burner ignition delay in CH mode
F18
(00-10 minutes) - 00=10 seconds
F19
Manufacturer information
F20
Manufacturer information
Anti-legionellosis function
F21
00 = Disabled - 01 = Enabled
F22
Manufacturer information
F23
Maximum DHW setpoint
F24
Manufacturer information
F25
No water safety device
F26...F29
Manufacturer information (read-only parameters)
F30
Manufacturer information
F31
Manufacturer information
F32...F41
Diagnostics (See Service instructions)
Final
Calibration function activation
parameter
(See Service instructions)
WARNING:
do not change the "manufacturer information" parameters.
INSTRUCTIONS FOR FITTERS

21. PARAMETER SETTINGS

-
(
) together and hold down for at least 6 seconds. When the function is active, the display
;
;
, on the display. "ESC" appears.
(0-100%)
Description of parameters
240/40 Fi - 240/60 Fi
240/40 i - 240/60 i
10
20
48
280/60 i
280/60 Fi
20
10
00 o 01
06
02
04
00
00
100
100
00
00
03
03
07
00
00
00
65
35
01
--
10
00
--
0