User's manual
Reminders
Fully discharge then recharge the battery every 3 month for longer battery life.
The backup time of the UPS depends on the connected devices and battery condition.
The batteries have self-discharge characteristic. It might happen that the battery capacity is already low
just out of box. Please charge the UPS for 8 hours before using its power.
If UPS cannot be found in software, please read appendix D in manual on CD.
Reset circuit breaker: (1) disconnect some devices on UPS; (2) push it back.
Replace battery : in case it is necessary,
Disconnect power
If you have any problems, go to
register at www.trust.com/register.
Type of UPS
Output capacity
Input
Voltage range
Frequency
Output
Frequency
Freq. regulation
Surge current protection [J]
Maximum surge current [Amp]
Transfer time (typical)
Battery type & number
Battery
Backup time (min.)
Charge time
Open front panel
Remove cover
www.trust.com/14951
for FAQ, drivers and manuals. For extensive service,

Technical specification

5
Extract wires on battery
Replace battery in
Line-Interactive UPS
1200 VA/600 W
230 VAC
170 ~ 280 VAC
47-63 Hz
230 VAC
50 o 60 Hz
+/- 1 Hz
Max. 150
6,500 A
Less than 3 ms
CSB GP1270(F2), 12V/ 7AH
2 pieces
38 ~ 70
8 hours to 90% after full discharge
UK