4
CONFIGURATION
Name
Display
Description
AVG
AUG
Setting the moving arithmetic
average
RST
rSt
Reset to factory settings
DSP
dSP
Display settings
DLY
dLY
Setting the time functions for
the switching outputs.
Q_1
q_I
Distance assignment for
switching output Q1.
Q_2
q_2
Distance assignment for
switching output Q2.
Q_3
q_3
Distance assignment for
switching output Q3. (only in
5-pin devices)
OFS
oFS
Defines the offset of the
switching threshold (cm) dur‐
ing the teach-in, based on the
currently measured value.
10
Value
Display
Initial
selection
value
don
Stb
Std
1, 4, 16,
64
64
64, 256
NO, YES
no
X
YES
ON, OFF
on
X
oFF
OFF, OFD,
oFF
X
OND, SHT
oFd
ond
Sht
0 ... 300
300
300
0 ... 300
300
300
0 ... 300
300
300
-50 ... +50 0
0
Description
Dark switching: The switching
output switches off when the
object is closer than the
taught sensing range.
The switching output Q1
issues the stability of the
measured value acquisition
(therefore corresponds to the
LED stability display). Light
switching functionality.
The switching output Q1
issues the stability of the
measured value acquisition
(therefore corresponds to the
LED stability display). Dark
switching functionality.
Sets the number of values
across which a moving arith‐
metic average is established
when the signal is output.
This smooths the signal out‐
put. The possible values are
1, 4, 16, 64, or 256 (e.g., 1 =
no averaging, 256 = average
across 256 values)
No reset.
Reset all values to factory set‐
tings with the exception of the
PNP/NPN selection.
Display shows display value in
cm.
Display switches off 30 sec‐
onds after an operating but‐
ton was last pressed.
No time function activated.
Switch-off delay, adjustable
from 0 ... 999 ms.
Switch-on delay, adjustable
from 0 ... 999 ms.
Single shot, adjustable from 0
... 999 ms.
Value range 0 ... 300
Value range 0 ... 300
Value range 0 ... 300
Value range -50 ... +50
8020034.ZX33 | SICK
Subject to change without notice