Keep the measuring tool, the laser target
plate 21 and the holder 10 away from cardi-
ac pacemakers. The magnets inside the
measuring tool, the laser target plate and the
holder generate a field that can impair the
function of cardiac pacemakers.
Keep the measuring tool, the laser target plate 21 and
the holder 10 away from magnetic data carriers and
magnetically sensitive devices. The effect of the mag-
nets inside the measuring tool, the laser target plate and
the holder can lead to irreversible data loss.
Product Description and Specifica-
tions
Please unfold the fold-out page with the representation of the
measuring tool and leave it unfolded while reading the operat-
ing instructions.
Intended Use
The measuring tool is intended for determining and checking
horizontal and vertical lines.
Technical Data
Cross-line Laser
Article number
1)
Working range, min.
Levelling Accuracy
Self-levelling range, typically
Levelling duration, typically
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
C
6
Tripod mount
– Cross-line Laser
– Holder
Batteries
Operating time, approx.
Automatic switch-off after approx.
Weight according to
EPTA-Procedure 01/2003
Dimensions
Degree of protection
1) The working range can be decreased by unfavourable environmental
conditions (e.g. direct sun irradiation).
The measuring tool can be clearly identified with the serial number 7 on
the type plate.
1 609 92A 0KH | (28.4.14)
Product Features
The numbering of the product features shown refers to the
illustration of the measuring tool on the graphic page.
1 Exit opening for laser beam
2 Tripod mount 1/4"
3 On/Off switch
4 Operating mode button
5 Automatic levelling indicator
6 Laser warning label
7 Serial number
8 Latch of battery lid
9 Battery lid
10 Holder
11 Locking screw for holder
12 Screw holes of holder
13 Opening for strap attachment
14 Magnets
15 1/4" tripod mount on holder
16 5/8" tripod mount on holder
17 Protective pouch
18 Tripod*
19 Laser viewing glasses*
GLL 2-15
20 Magnets laser target plate
3 601 K63 7..
21 Laser target plate*
15 m
22 Measuring plate with stand
±0.3 mm/m
23 Universal holder BM 1*
±4°
24 Telescopic rod*
<4 s
* The accessories illustrated or described are not included as
standard delivery.
–10 °C ... +50 °C
–20 °C ... +70 °C
Assembly
90 %
2
Inserting/Replacing the Batteries
635 nm, <1 mW
Alkali-manganese batteries are recommended for the meas-
1
uring tool.
To open the battery lid 9, press the latch of the battery lid 8 in
1/4"
the direction of the arrow and remove the battery lid. Insert
1/4"; 5/8"
the supplied batteries. When inserting, pay attention to the
3 x 1.5 V LR06 (AA)
correct polarity according to the representation on the inside
of the battery compartment.
15 h
When the batteries become weak, the laser beams flash rap-
120 min
idly for about 5 s (while the measuring tool is switched on).
Always replace all batteries at the same time. Only use batter-
0.3 kg
ies from one brand and with the identical capacity.
80 x 42 x 96 mm
Remove the batteries from the measuring tool when
IP 5X (dust protected)
not using it for extended periods. When storing for ex-
tended periods, the batteries can corrode and self-dis-
charge.
Bosch Power Tools