Fuel Gauge; Low Battery Indication; Charge - Milwaukee L4 CLL Manual Original

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54

FUEL GAUGE

After switch on or switch off the laser the fuel gauge will display the battery life for 3 seconds
Green solid
100% - 50% remaining
Yellow solid
49% - 11% remaining
Red solid
10% - 3% remaining
Red fl ashing
3% - 0% remaining

LOW BATTERY INDICATION

When the voltage is low, the laser switch to power safe mode.
The laser will blink in self leveling mode
4 sec.
1 sec.
The laser will blink in manual mode
8 sec.
From now on it is still possible to continue the work.
When the voltage is too low, the laser and the LED will fl ash 3 times and it automatically shuts
down.
ENGLISH
1 sec.

CHARGE

It is possible to work with the laser during charge.
1
2
Red breathing
Charging, 0-49% charged
Yellow breathing
Charging, 50-99% charged
Green solid
100% charged
Red/Green fl ashing
No battery, damaged battery, faulty battery, over temperatur
Red breathing
Charging during use
Green fl ashing
No battery inserted during use
3
DC
5 V
0,1 - 2,1 A
5
Tabla de contenido
loading

Este manual también es adecuado para:

L4 cllp

Tabla de contenido