MAINTENANCE
Wipe the aperture lens and the body of the cross laser with a clean soft cloth. Do not use
solvents.
Although the cross laser is dust and dirt resistant to a certain degree, do not store in dusty
places as long term exposure may damage internal moving parts.
If the cross laser is exposed to water, dry the laser level before returning it to the carrying case
to prevent corrosion damage.
TECHNICAL DATA
Laser Class
Self-Leveling Range
Self-Leveling Time
Battery technology
Voltage DC
USB input
DC output
AC/DC Adaptor Input
AC/DC Adaptor Ouput
Charging time
Power input
Protection class (water and dust
protection)
Max. altitude
Relativ air humidity max.
Pollution degree according to
IEC 61010-1
Pulse duration t
P
Functions
L4 CLL horizontal, vertical, cross line
L4 CLLP horizontal, vertical, cross line,
Frequency
Projections
Diode Quantity
Diode type
Laser beams output pattern
L4 CLL Single horizontal, single vertical, cross line
L4 CLLP Single horizontal, single vertical + 2 plump dots up and
Operating time
Tripod mount
ENGLISH
2
± 4°
≤ 3 s
Li-Ion
4 V
5 V DC; 2.1 A max.
4 V
2.1 A
100-240 V ~ 50/60 Hz; 0.6 A max.
5 V
2.1 A; 10.5 W
≤ 130 min
1,5 W @ 4.2 V
IP54
2000 m
80%
2*
≤ 70 μs
plumb function (2 points)
10 kHz
2 lines green, 2 points green
2
30 mW
down , cross line + 2 plumb dots (up and down).
8 hrs
1/4" thread
Suitable detector
Laser Line
Width < 9.53mm @ 30m
Wavelength 510 - 530 nm Laser Class II
Max. Power ≤ 7 mW
Accuracy +/- 3 mm / 10 m
Fan angle Vertical Line > 120°; Horizontal Line > 120°
Colour green
Working Range 30 m (with detector 50 m)
Laser plumb (L4 CLLP only)
Laser point wavelength 510 - 530 nm Laser Class II
Laser point max. power < 1 mW
Plumb accuracy +/- 3 mm / 10 m
Laser point colour green
Working Range 30 m
Recommended ambient operating
temperature
Storage Temperature
Recommended ambient charging
temperature
Recommended battery types
Recommended USB Power Supply
Dimensions
Weight (incl. Battery)
L4 CLL 995 g
L4 CLLP 998 g
* Only non-conductive deposits occur, wherby occasional temporary conductivity caused by
condensation is expected.
SPECIFIC CONDITIONS OF USE
The product is designed for mainly indoor use. For outdoor use make sure that the boundary
conditions are the same as for indoor use.
The laser is innovatively designed for a very broad range of professional jobs, including:
- Aligning tiles, marble, cabinets, borders, moldings and trimmings
- Marking layout for doors, windows, rails, stairs, fences, gates, decks and pergolas installation.
- Transferring reference point for light installations, vents, transfer of heights, levelling perimeter
walls, wall studs, setting out tracks on fl oors and all other professional use.
- It is intended for determining and checking horizontal and vertical lines.
Do not use this product in any other way as stated for normal use.
Milwaukee LLD50
-10°C - +40 °C
-20°C - +60 °C
5°C - +60 °C
L4B3
CUSB
135 mm x 61 mm x 97 mm
2