Cleaning Battery And Battery Compartment; Troubleshooting - Echo DPB-2500 Manual Del Operador

Ocultar thumbs Ver también para DPB-2500:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

DPB-2500

Cleaning Battery and Battery Compartment

1.
Clear the unwanted material out of the
air vent with a vacuum cleaner.
2.
Do not spray the air vent or put the air
vent in solvents.
3.
Clean the battery compartment (8) and
the plastic components with a moist
and soft cloth.

TROUBLESHOOTING

Problem
The motor does not
start when you pull
the trigger switch.
The air does not flow
through the tube
when you start the
machine.
99922205730
© 08/2021 ECHO Incorporated
Cause
The battery is not
installed tightly.
The battery is out of
power.
The trigger switch is
defective.
The motor is defective.
The air inlet or tube
outlet has a blockage.
TROUBLESHOOTING
8
Solution
Make sure that
you tighlty install
the battery in the
machine.
Charge the battery.
Replace the defective
parts, call an
Authorized ECHO
Dealer
Remove the blockage.