-Px1xx
-Px2xx
-Px3xx
-Px4xx
D.ON, PNP: Q (≤ 100 mA)
-Nx1xx
-Nx2xx
-Nx5xx
-Nx6xx
L.ON, NPN Open Collector Q (≤ 100 mA)
-Nx1xx
-Nx2xx
-Nx3xx
-Nx4xx
D.ON, NPN Open Collector Q (≤ 100 mA)
Table 4: Test input
GS6L
The test input is always connected to Q
Test input, low active (≤ 2 mA)
7
Commissioning
7.1
Alignment
8025390 | SICK
Subject to change without notice
Align the sender with the receiver. Select the position so that the red emitted light beam
hits the receiver. Tip: Use white paper or a reflector as an alignment aid. The sender
must have a clear view of the receiver, with no object in the path of the beam [see
figure
0]. You must ensure that the optical openings (front screen) of the sensors are
completely clear.
+ (L+)
Q
‒ (M)
+ (L+)
+ (L+)
Q
Q
! (M)
! (M)
+ (L+)
Q
! (M)
+ (L+)
Test
– (M)
7
COMMISSIONING
+ (L+)
Q
‒ (M)
+ (L+)
Q
! (M)
+ (L+)
+ (L+)
Q
Q
! (M)
! (M)
+ (L+)
Test
– (M)
9