Troubleshooting - GYS BATIUM 7/12 Manual Del Usuario

Ocultar thumbs Ver también para BATIUM 7/12:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11

TROUBLESHOOTING

SYMPTOM
The charge indicator 1 does not switch on.
The battery voltage indicators (A) flash one
1
by one after one minute of charge
The battery capacity indicators (B) flash
2
one by one.
When the battery is connected:
The indicator for charge 1 does not switch
on.
The battery voltage indicator (A) and (B)
3
capacity indicator switch on.
The «SOS Recovery» indicator flashes 6
4
after one minute of charge
"SOS recovery" function (Batium 15/12 –
15/24) :
5
After 24 hours of use, the charge indicator
1 and end of charge indicator 2 are off.
Forced charging function: After pressing for
5 seconds the battery voltage selection key
6
3 to start the forced charging function, the
indicator does not switch on.
When you connect the BATIUM to the
7
mains, no indicators switch on
WARNING
• WARNING! Explosive gas, avoid flames and sparks. During charging, the battery should be placed in a ventilated area.
• Protect the unit from rain and moisture
• If the power cable is damaged it must be replaced by the manufacturer, its after sales department or a similarly qualified person
to avoid hazard.
• The external fuse can be replaced and the circuit breaker can be engaged by the user.
• Under no circumstances should this appliance should be used to charge accumulators or non rechargeable batteries.
• Respect the connection sequence indicated.
• Product subject to separate collection, do not dispose in domestic waste.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or
lack of experience or knowledge, unless they are supported by a person responsible for their safety, supervision or instruction
concerning use of the appliance.
• Do not open the device. Modifications not performed by the manufacturer's technician will void the warranty.
• Check that the available input voltage corresponds to the one indicated on the nameplate of the charger.
• Do not short-circuit the clamps during charging.
BATIUM 7/12 • 7/24 • 15/12 • 15/24
BATIUM 7/12 • 7/24 • 15/12 • 15/24
REASONS
Incorrect battery voltage selected.
The battery is unrecoverable
Battery in short-circuit or damaged
A consumer is left on (eg : Headlights)
The charger is being used as a power
supply to compensate high consumers
connected to the battery.
The battery has a higher capacity (Ah) than
the charger's capability.
You have selected a battery capacity (Ah)
lower than the one indicated on your
battery
The battery voltage does not rise. The
battery is damaged
Polarities + and – have been reversed
Weak clamp connection
The battery is deeply discharged
The fuse has blown
You battery is deeply discharged – and has
started to sulphate.
The charge continues but it is recom-
mended to use the "SOS recovery" function
The battery is unrecoverable
Battery voltage <0.5V
The charger has detected a problem with
the main voltage
REMEDIES
- Disconnect BATIUM from the battery but keep the
BATIUM connected to the mains.
- Select the correct voltage
- Re-connect the BATIUM to the battery
Replace the battery
Replace the battery
Turn off the consumer then continue or re-start the
charge
Normal behaviour of the charger in this use. The
indicator which indicates the charge end cannot
switch on.
The charging time will be abnormally long. If pos-
sible use a more powerful charger
Select the correct capacity as indicated on your
battery.
Replace the battery
Put the red clamps on + and black clamps on -
Clean the battery terminals and re-connect the
clamps.
Use the « forced charge » function (see procedure
on previous page)
Disconnect the Batium from the power supply.
Disconnect the clamps from the battery. Replace
the fuse: 15A for Batium 7-12 and 7-24, and 30A
for Batium 15-12 and 15-25.
Disconnect the device from the mains and then
disconnect the clamps.
Engage the « SOS Recovery » function (see proce-
dure on previous page).
Replace the battery
Replace the battery
Disconnect the Batium for 10 sec., then connect
again.
EN
7
Tabla de contenido
loading

Este manual también es adecuado para:

Batium 15/12Batium 7/24Batium 15/ 241331061

Tabla de contenido