Removal Of Front Grille; Removimiento Del Montaje De La Rejilla Frontal; Remove The Air Filter Quite El Filtro De Aire; Electrical Work - Panasonic CW-C180EG Instrucciones De Operación

Tabla de contenido
AIR CONDITIONER INSTALLATION
AIR CONDITIONER INSTALLATION
INSTALACIÓN DEL ACONDICIONADOR DE AIRE
INSTALACIÓN DEL ACONDICIONADOR DE AIRE

Removal of Front Grille

Removimiento del Montaje de la Rejilla Frontal

1
Remove the Front Intake Grille
Raise the grille by approximately 90°. Slide it to the left to unhinge
then pull outwards.
Quite la Rejilla Frontal de Toma de Aire
Levante la rejilla a unos 90˚ aproximadamente. Deslicela hacia la
izquierda para desmontarla luego tire hacia afuera.
3
a
Remove the Front Grille
Open the control panel cover.
When performing the following steps, do not pull the bottom edge of the front grille towards
b
you more than 3 inches or you may damage the top tabs.
Press inwards on the cabinet near the bottom right side of the front grille while pulling the front
c
grille to the right then slightly towards you to release the right tab.
Press inwards on the cabinet near the bottom left side of the front grille while pulling the front
d
grille to the left then slightly towards you to release the left tab.
Slide the front grille upwards to release the two top tabs.
3
a
Quite la Rejilla Frontal
Abra la cubierta del panel de control.
Cuando se realicen los siguientes pasos, no tire el borde inferior de la rejilla frontal en su dirección más de 3 pulgadas o puede
b
dañar las lengüetas superiores.
Presione hacia adentro en el gabinete cerca del lado inferior derecho de la rejilla frontal mientras tira de la rejilla frontal hacia la
c
derecha y luego un poco hacia usted para liberar la lengüeta derecha.
Presione hacia adentro en el gabinete cerca del lado inferior izquierdo de la rejilla frontal mientras tira de la rejilla frontal hacia la
d
izquierda y luego un poco hacia usted para liberar la lengüeta izquierda.
Deslice la rejilla frontal hacia arriba para liberar las dos lengüetas superiores.

Electrical Work

• Always use at the rated voltage and with a specific air conditioning circuit.
• Some installation locations may require the installation of a shortcircuit breaker.
• Time delay fuse or circuit breaker rating is 16 Ampere for CW-C180EG/CW-A180EG and 20 Ampere for CW-C240EG.
• Nominal cross sectional area of power supply wire must be 3 core x 2.5 mm
• The power supply must be from an independent circuit.
• All electrical installations must be made in accordance with local wiring and safety regulations wherever applicable.
• There must be a double pole switch with a minimum of 3 mm contact gap in the fixed installation circuit.
• Please engage an authorized dealer or specialist for the installation work.
Trabajo Eléctrico
• Utilícese siempre en voltage estimado y con un circuito específico de Acondicionador de aire.
• Algunos tipos de lugares para instalación pueden requerir la instalación de un rompe corto circuito.
• El fusible de retardo de tiempo o cortacircuito es de 16 Amperios para CW-C180EG/CW-A180EG y 20 Amperios para
CW-C240EG.
• El área de la sección cruzada nominal del cable de suministro eléctrico debe de ser 3 corazón x 2,5 mm
• La fuente de alimentación debe de provenir de un circuito independiente.
• Toda instalación eléctrica debe ser lievada a cabo de acuerdo con el alambrado local y las regulaciones de seguridad que
deban ser aplicadas.
• Debe haber un interruptor bipolar con una separación minima entre contactos de 3 mm en el circuito de instalación.
• Por favor contectar a un comerciante autorizado o especialista para hacer el trabajo de instalación.
15
CW-C180/240EG(11~16)
12
2
Remove the Air Filter
Quite el filtro de aire
Air filter
Filtro de aire
Lift filter by the holder and pull outwards.
Levante el filtro por el soporte y tire hacia afuera.
2
or above.
2
29/5/01, 8:23 pm
HIGH
FAN
COOL
LOW
HIGH
COOL
o más.
Tabla de contenido
loading

Este manual también es adecuado para:

Cw-c240egCw-a180eg

Tabla de contenido